Record 1Public property record

HVAC Seasonal Maintenance — Flame sensor cleaned, filter changed

  • HVAC

On November 21, 2025, ASSURED HEATING AND COOLING documented HVAC at 1009 Lindeman Road, St. Louis, MO 63131.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$89

    Seasonal maintenance: cleaned the flame sensor and changed the filter, reassembled the system and confirmed it was working correctly; system is in good condition.

  • HVACWork status not resolved

    Photograph shows a removed furnace spark igniter electrode assembly with ceramic insulator, metal mounting flange, L-shaped metal rod, and forked electrode tip, along with a partial view of what appears to be a high-voltage ignition cable connector.

  • HVACWork status not resolved

    Photograph shows a removed furnace spark igniter electrode assembly with ceramic insulator, metal mounting bracket, forked electrode tip, and L-shaped terminal rod, resting on a denim surface.

  • HVACWork status not resolved

    Photograph shows one visibly used/dirty 16x25x1 HVAC air filter alongside one new/clean 16x25x1 replacement filter laid on a concrete basement floor; a handwritten date notation is visible on a small card beneath the new filter.

  • HVACWork status not resolved

    Photograph shows an HVAC blower wheel (squirrel cage fan) with heavy accumulation of dust and debris coating all visible blades and the center hub, indicating the unit has not been cleaned in an extended period.

  • HVACWork status not resolved

    Photograph shows the interior of a furnace with the access panel open, revealing multiple cylindrical heat exchanger cells illuminated by a light source, consistent with a heat exchanger inspection.

Record 2Public property record

HVAC AC Service — Mouse nest removed, loose wire repaired

  • HVAC

On May 1, 2026, ASSURED HEATING AND COOLING documented HVAC at 1009 Lindeman Road, St. Louis, MO 63131.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$99

    AC service: changed the filter (16/25/1) at the outdoor unit, confirmed the drain is clear on an older R-22 system, removed a mouse nest from the outdoor AC and repaired a loose wire.