- HVAC · Furnace and condensing unit replaced with new coil · Sep 2024
- HVAC · Theft deterrent cage installed over outdoor condensing unit · Sep 2024
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 1 documented record for 10131 Monarch Drive, St. Louis, MO 63136, dated in September 2024. The amount summary includes $6,419.11 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Installation — 2-ton A/C + 80% furnace install
- HVAC
Built from Housecall Pro data
- $6,419HVACInstalled a 2 ton 13 SEER condensing unit, an 80% 50,000/75,000 BTU furnace and a coil with R410A, plus a theft deterrent cage.
- HVACPhotograph shows a gray upflow furnace installed in a basement mechanical room, connected to sheet metal supply ductwork above, with a metal flue/exhaust pipe, flexible electrical conduit, and gas supply line with shutoff valve visible; unit appears to be in good condition.
- HVACPhotograph shows a basement mechanical area with a sheet metal supply plenum and ductwork connected to a central masonry column, a furnace/air handler unit, and a water heater visible to the right, with a flexible hose running across the concrete floor.
- HVACPhotograph shows an outdoor central air conditioning condenser unit installed on a pad adjacent to the home's foundation wall, with insulated refrigerant line set running along the wall into the structure and a disconnect box mounted on the exterior brick.
- HVACPhotograph shows an outdoor air conditioning condenser unit installed on a pad against the exterior brick wall, with refrigerant/electrical lines running up the wall to a disconnect box; a utility meter or timer device is also visible to the left.
Documented warrantyfive-year / ten-year / twenty-yearFrom invoiceView details
What this warranty covers
- parts
· source
“manufacturer five-year parts warranty”
- compressor
· source
“ten-year compressor warranty”
- parts
· source
“Once the equipment has been properly registered, the five-year manufacturer parts warranty becomes a ten-year parts warranty.”
- labor
· source
“Contractor offers a ten-year labor warranty on all new equipment installed by contractor.”
- heat exchanger
· source
“a twenty-year heat exchanger warranty”
Coverage based on an invoice. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.
HVAC
HVAC
HVAC