On July 29, 2026, Greensmith Home Inspection llc documented Electrical, Foundation, HVAC, and 7 other topics at 10333 Castle Drive, St. Louis, MO 63136.
- Record date
Available findings
- SewerWork status not resolved
No damages observed to the sewer lateral lines; however, heavy scaling in the cast-iron section has reduced the pipe diameter to the point where the inspector could not make the final turn towards the city main — lines need to be cabled/cleared.
- PestWork status not resolved
Visible evidence of wood destroying insects observed: termite damage present around wood window frames; borate-based solution treatment recommended.
- ElectricalWork status not resolved
Cutler Hammer electric panel is older, has rusted through, and needs replacement; panel wiring appears mostly intact but could not be tested due to no power; tree limbs are pushing on overhead power lines and require utility company trimming; smoke detectors are non-functional.
- FoundationWork status not resolved
Basement is very damp with moisture originating from unsealed wall cracks; epoxy injections recommended to seal cracks; perimeter insulation is absent.
- Home InspectionWork status not resolved
Whole-home inspection of 10333 Castle Drive found extensive deficiencies including stripped HVAC and plumbing systems, a rusted electrical panel, termite damage, mold, and a 15-year-old roof with improperly overlaid shingles; no structural deficiencies were observed.
- HVACWork status not resolved
Gas furnace and AC condenser have been removed and ductwork destroyed; entire HVAC system needs replacement; exhaust duct also needs replacement.
- MoldWork status not resolved
Mold and mildew are present on interior walls and ceilings, likely resulting from basement moisture infiltrating through unsealed wall cracks.
- PestWork status not resolved
Older termite damage observed around window frames; replacement of damaged wood and treatment with a borate-based solution (Bora-Care) recommended unless seller proves prior treatment.
- PlumbingWork status not resolved
All plumbing supply lines have been removed and home needs to be re-plumbed with modern materials; 2006 Craftsman 40-gallon gas water heater has been stripped for parts and needs replacement; exterior faucet supply lines have been cut and are disconnected.
- RoofWork status not resolved
15-year-old 3-tab shingle roof shows signs of wear; newer shingles were incorrectly nailed on top of old shingles and need removal with damaged shingles replaced; gutters are pulled away from the home and need reset or replacement; wood soffit is aged and damaged.
- WindowsWork status not resolved
Four windows have broken seals and one window pane is cracked; all five panes need replacement, and missing exterior siding should be replaced as needed.