10344 Earl Drive
Across 9 records on this home
Completed work
Invoices and paid receipts
Estimated · not confirmed
Quotes, estimates, and other amounts not confirmed as performed
Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 9 documented records
Fresh House Property Summary
Highlights selected from 9 documented records for this property.
- HVAC · Furnace carbon monoxide test reached dangerous levels; gas shut off · Nov 2026
- HVAC · Outdoor unit dual capacitor replaced and broken fan wire repaired · Aug 2026
- HVAC · Outdoor unit repaired after broken high-voltage wire found · Jul 2025
- HVAC · AC system found low on refrigerant with multiple lineset leaks · Oct 2026
- HVAC · Furnace replacement needed; estimate on file but not confirmed complete · Nov 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 9 documented records for 10344 Earl Drive, St. Louis, MO 63136, dated from July 2025 through November 2026. The amount summary includes $1,454.73 in completed work across HVAC, $7,580.88 in estimates; appraisal values and permit-declared valuations are excluded.
HVAC Repair — Capacitor replaced, broken fan wire repaired
- HVAC
Built from Housecall Pro data
- $474HVACOutdoor unit was not coming on; tested and replaced the 35 + 5 Mfd dual capacitor, then traced wires, found and repaired a broken fan wire, and the system ran as intended.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — No AC call; system working as intended
- HVAC
Built from Housecall Pro data
- $154HVACService call for no AC; upon arrival the system was found working as intended, with thermostat set at 70 and currently at 71.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Line Set Estimate — New 50ft line set and R410a recharge
- HVAC
Option: Option #1 $2,608.67 (no decision recorded)
Built from Housecall Pro data
- $2,609HVACEstimate for recovering refrigerant, vacuum and installing a liquid drier, installing a new 3/4 - 3/8 line set up to 50ft from indoor coil to outdoor condenser, adding R410a by the pound, and labor.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Leak Search Service — Multiple lineset leaks
- HVAC
Built from Housecall Pro data
- $485HVACService call for no AC; multi halide/electronic leak search found system low on R410 refrigerant with multiple leaks in the lineset, and evacuating the system, running a new lineset with pressure test, vacuum and refrigerant refill was recommended.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC No Heat Repair — Dangerous CO levels; furnace needs replacing
- HVAC
Built from Housecall Pro data
- $325HVACNo-heat call: cleared debris from a stuck inducer motor, ran a carbon monoxide test on the heat exchanger that reached dangerous levels, turned gas to the furnace off for safety; furnace will need to be replaced.
- HVACPhotograph shows the interior of a gas furnace with significant rust and corrosion visible on the heat exchanger surfaces, an inducer motor assembly with a WARNING label, multiple wiring harnesses and connectors, and part number stickers (PN-102907-01).
- HVACPhotograph shows a purple-jacketed wire/cable and additional darker wiring routed through a tight, confined space alongside a corrugated metal structure, with visible dust accumulation and surface corrosion/oxidation on surrounding metal components.
- HVACPhotograph shows a vertical copper pipe with an inline brass ball valve fitted with a red lever handle; the pipe surface exhibits oxidation, and ASME markings are visible on the valve body.
- HVACPhotograph shows a Carbon Monoxide Meter with probe inserted into a ceiling HVAC vent register, displaying a current CO reading of 108 ppm and a maximum recorded reading of 236 ppm, with the alarm indicator light illuminated red.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Furnace Install Estimate — Rheem 80% 75,000 BTU furnace install
- HVAC
Option: Option #1 $4,647.61 (no decision recorded)
Built from Housecall Pro data
- $4,648HVACEstimate for Option #1: Payment Terms, Furnace Only Install Description (This quote will include the following, sheet metal work to adapt to new), Terms and Conditions, Equipment Warranty, 80% 75,000 BTU Furnace (We purpose to install the following equipment in your home).
Documented warrantyfive-year / ten-year / twenty-yearFrom estimateView details
What this warranty covers
- parts
· source
“All equipment installed by Contractor comes with a manufacturer five-year parts warranty”
- compressor
· source
“ten-year compressor warranty”
- parts
· source
“Once the equipment has been properly registered, the five-year manufacturer parts warranty becomes a ten-year parts warranty.”
- labor
· source
“Contractor offers a ten-year labor warranty on all new equipment installed by contractor.”
- heat exchanger
· source
“a twenty-year heat exchanger warranty”
Coverage based on an estimate. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — Broken high voltage wire at outdoor unit fixed
- HVAC
Built from Housecall Pro data
- $154HVACService call for an outdoor unit that would not come on; found a broken high voltage wire, fixed it, and the system worked as intended after restart.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Seasonal Maintenance — Flame sensor cleaned, filter replaced
- HVAC
Built from Housecall Pro data
- $89HVACSeasonal maintenance performed: system working as it should, flame sensor cleaned and filter replaced (16x20x1), and system confirmed running correctly before leaving.
- HVACPhotograph shows the interior of a furnace with active blue flames visible at the burners, multiple exposed wiring harnesses (purple, white, green/yellow, teal) with connectors, visible rust/corrosion on metal surfaces, and debris/dust accumulation on the unit floor.
- HVACPhotograph shows a top-down view into an outdoor HVAC condenser unit, revealing the fan blade assembly and motor hub with significant dark dirt and debris accumulation on the fan blades and interior housing surfaces.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — AC 4 yrs old, good condition
- HVAC
Built from Housecall Pro data
- $99HVACAC service call (AC CC) performed; AC unit is 4 years old and in good condition, filter size 16x20x1.