Property records for 10356 Oxford Hill Drive, St. Louis, MO 63146
All 7 public upload records returned by the Fresh House property feed are available across 1 server-rendered page. This page shows records 1 to 7.
Record details are source-backed where available. Permit status and descriptions repeat the publishing agency's data; they do not independently establish that work was completed.
HVAC Coil Replacement — 2-ton R410A condenser and coil replaced
HVAC
On August 21, 2023, ASSURED HEATING AND COOLING documented HVAC at 10356 Oxford Hill Drive, St. Louis, MO 63146.
Record date
Documented details
Outcome: Paid in full
Available findings
HVACCompleted work$3,924
AC coil replacement: installed a Sure Comfort by Rheem/WeatherKing 2 Ton R410A condensing unit and cased/uncased 2 Ton R410A coil.
Record 2·Public property record·8
HVAC Service Call — System functioning; no duct blockages found
HVAC
On January 18, 2024, ASSURED HEATING AND COOLING documented HVAC at 10356 Oxford Hill Drive, St. Louis, MO 63146.
Record date
Documented details
Outcome: Paid in full
Available findings
HVACCompleted work$75
No heat service call: system found functioning as intended; tenants reported one vent not blowing as hard as desired, and inspection found no blockages or damage to ductwork.
Record 3·Public property record·1
HVAC Control Board Replacement — Control board replaced
HVAC
On January 23, 2024, ASSURED HEATING AND COOLING documented HVAC at 10356 Oxford Hill Drive, St. Louis, MO 63146.
Record date
Documented details
Outcome: Paid in full
Available findings
HVACCompleted work$145
Replaced control board with customer supplied part.
Record 4·Public property record·6
HVAC Installation — 2-ton R410A condenser and coil installed
HVAC
On April 22, 2024, ASSURED HEATING AND COOLING documented HVAC at 10356 Oxford Hill Drive, St. Louis, MO 63146.
Record date
Documented details
Outcome: Paid in full
Available findings
HVACCompleted work$3,924
Installed a Sure Comfort by Rheem/WeatherKing 2 Ton R410A condensing unit and cased/uncased 2 Ton coil because the existing system was empty on R22 and the compressor was shorted.
Record 5·Public property record·10
HVAC Replacement — 2-ton R410A condenser and coil replacement
HVAC
On April 23, 2024, ASSURED HEATING AND COOLING documented HVAC at 10356 Oxford Hill Drive, St. Louis, MO 63146.
Record date
Documented details
Outcome: Paid in full
Available findings
HVACCompleted work$3,924
Installed a Sure Comfort by Rheem/WeatherKing 2 ton R410A condensing unit and 2 ton cased/uncased coil, replacing an R22 system with multiple leaks in the coil and service valves.
Record 6·Public property record·8
Plumbing Water Heater Installation — 40/50 gallon water heater
Plumbing
On April 29, 2024, ASSURED HEATING AND COOLING documented Plumbing at 10356 Oxford Hill Drive, St. Louis, MO 63146.
Record date
Documented details
Outcome: Paid in full
Available findings
PlumbingCompleted work$2,050
Installed a 40/50 gallon gas/electric water heater, attached to existing copper lines with flex lines using the existing flue, including gas line, expansion tank and other code requirements.
Record 7·Public property record
HVAC Coil/Condenser Replacement — 2-ton R410A condenser and coil
HVAC
On August 16, 2024, ASSURED HEATING AND COOLING documented HVAC at 10356 Oxford Hill Drive, St. Louis, MO 63146.
Record date
Documented details
Outcome: Paid in full
Available findings
HVACCompleted work$3,900
Work performed: Coil/Condenser 2 Ton R410A System (We propose to install the following equipment in above listed unit); Equipment Warranty; Payment Terms Net 30/45; Terms and Conditions.
HVACWork status not resolved
Photograph shows a gas furnace unit installed in an unfinished basement or utility space, with a large sheet-metal supply plenum above, a vertical flue/exhaust pipe, black iron gas supply piping, copper tubing, and a flexible hose connection visible.
HVACWork status not resolved
Photograph shows two brass refrigerant service valves with pink caps labeled 'R-410A' and 'R-417A' at the side of an outdoor condenser unit, with insulated suction line and copper liquid line connected.
HVACWork status not resolved
Photograph shows Fieldpiece app screen displaying R-410A refrigerant-side measurements: suction pressure 120.9 psig, suction temperature 58.0°F, vapor saturation 40.9°F, actual superheat 17.1°F; liquid pressure 316.0 psig, liquid temperature 82.1°F, liquid saturation 99.4°F, actual subcooling 17.3°F.
HVACWork status not resolved
Photograph shows a metal HVAC unit (possibly a furnace or air handler) wrapped in foil or plastic sheeting with visible red labeling, copper refrigerant tubing, black pipes/conduits, and a cylindrical metal component to the right, all located in a confined utility space.