Complete public upload archive

Property records for 104 Gay Avenue, Clayton, MO 63105

All 8 public upload records returned by the Fresh House property feed are available across 1 server-rendered page. This page shows records 1 to 8.

Record details are source-backed where available. Permit status and descriptions repeat the publishing agency's data; they do not independently establish that work was completed.

Return to the property overview
Record 1Public property record

HVAC Diagnostic Service — Commercial diagnostic service and labor

  • HVAC

On June 10, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 104 Gay Avenue, Clayton, MO 63105.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$270

    Performed a commercial diagnostic service and commercial labor at the service address.

Record 2Public property record

HVAC Diagnostic Service — Commercial diagnostic service

  • HVAC

On July 8, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 104 Gay Avenue, Clayton, MO 63105.

Record date

Available findings

  • HVACCompleted work$140

    Performed a commercial diagnostic service at the Clayton, Missouri property.

Record 3Public property record

HVAC Compressor Replacement — New compressor for unit 1

  • HVAC

On July 13, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 104 Gay Avenue, Clayton, MO 63105.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$3,321

    New compressor for unit 1, with replacement suction line dryer, acid scavenger, liquid line dryer, capacitor, and new virgin R410A; the 2013 unit seems to be in good shape.

  • HVACWork status not resolved

    Photograph shows the interior of an outdoor condenser unit with the top removed, revealing a black dome compressor, copper refrigerant lines with visible corrosion/oxidation, multi-colored electrical wiring, and significant debris and fibrous material accumulated on the base pan.

  • HVACWork status not resolved

    Photograph shows copper refrigerant lines connected to a black fitting/cap at an HVAC unit, with visible ice or frost accumulation on and around the fitting and white residue on the left side; the condenser coil fins are visible in the background.

  • HVACWork status not resolved
Record 4Public property record

HVAC Recommissioning and Air Balance — Recommissioned, air balanced

  • HVAC

On July 14, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 104 Gay Avenue, Clayton, MO 63105.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$775

    Recommissioned and air balanced all 4 split systems on site, with lofts 8, 6, 5, and 4 made accessible.

  • HVACWork status not resolved

    Photograph shows a ceiling-mounted air handler unit with visibly torn and peeling foil-faced insulation, connected to round sheet-metal supply ductwork; insulation damage is present in multiple areas on the unit casing.

  • HVACWork status not resolved

    Photograph shows a large louvered rooftop unit (consistent with a cooling tower or air handling unit) with a dark metal frame and horizontal slat panels, alongside additional HVAC condensing units, all mounted on a white membrane flat roof.

  • HVACWork status not resolved

    Photograph shows a large rooftop air handling unit with a louvered intake face mounted on a white metal enclosure, flanked by two outdoor condenser units, situated between a flat metal roof and a sloped asphalt shingle roof.

  • HVACWork status not resolved

    Photograph shows a rooftop HVAC condenser unit (dark gray) alongside a large louvered mechanical panel and a white wedge-shaped curb or air handler enclosure, all situated on or adjacent to a light-colored metal roof.

  • HVACWork status not resolved

    Photograph shows exposed spiral galvanized steel HVAC supply ductwork running across the ceiling of a commercial space, with a wye/tee branch fitting, suspended from white-painted structural bar joists alongside recessed and track lighting fixtures.

  • HVACWork status not resolved

    Photograph shows what appears to be one or more HVAC condensing units visible at the rear right corner of the building, partially obscured by a wooden fence enclosure.

  • HVACWork status not resolved

    Photograph shows exposed galvanized sheet metal HVAC ductwork with elbow and transition fittings mounted at ceiling level, alongside a track lighting/speaker rail system and white structural framing with vapor barrier sheeting.

  • HVACWork status not resolved

    Photograph shows exposed ceiling-mounted rectangular sheet metal trunk ductwork with multiple round galvanized spiral duct branches, supported by metal strut framing, with insulated duct wrap visible in the upper right area.

Record 5Public property record

HVAC Control Board Estimate — Furnace 4 failed fan relay

  • HVAC

On July 14, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 104 Gay Avenue, Clayton, MO 63105.

Record date

Available findings

  • HVACEstimate or proposed work$589

    Estimate for replacing the furnace control board on furnace 4, which has a failed cooling fan relay and was previously wired to run the fan anytime the unit is powered.

Record 6Public property record

HVAC Duct Insulation — Duct insulation

  • HVAC

On July 24, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 104 Gay Avenue, Clayton, MO 63105.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$3,850

    Duct insulation was performed at the service address.

Record 7Public property record

HVAC Diagnostic Service — Commercial after-hours diagnostic and labor

  • HVAC

On July 29, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 104 Gay Avenue, Clayton, MO 63105.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$450

    Commercial after-hours diagnostic and labor performed for a maintenance customer at the service address.

  • HVACWork status not resolved

    4TTR6060B1000AA, Serial No. 13181TMB2F, manufactured 4/2013) with AHRI Certified label unit operates on HFC-410A refrigerant, 208/230V, 60Hz

  • HVACWork status not resolved

    Fieldpiece diagnostic measurements show air-side Delta T of 20.3°F with return dry bulb 78.0°F and supply dry bulb 57.7°F; supply relative humidity 89.9% and return relative humidity 55.7%; refrigerant side not yet linked.

  • HVACWork status not resolved

    Photograph shows four ecobee smart thermostats mounted on a wall, numbered 1 through 4, all powered on and displaying indoor temperatures ranging from 71°F to 74°F and an outdoor temperature of 99°F; a small wall gap is visible above thermostat #2 and two loose screws are visible on the wall below thermostat #3.

  • HVACWork status not resolved

    Photograph shows four ecobee smart thermostats mounted on a wall, labeled 1, 2, and 3 (fourth unit unlabeled), each displaying indoor and outdoor temperature readings; minor wall damage visible near unit 2 and two loose screws on the wall below unit 3.

  • HVACWork status not resolved

    Photograph shows a Fluke 323 True RMS Clamp Meter reading 21.9 A AC being taken on an outdoor HVAC condenser unit, with a JARD capacitor and associated wiring visible in the background.

Record 8Public property record

HVAC Labor Service — 1.5 hours commercial labor

  • HVAC

On July 30, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 104 Gay Avenue, Clayton, MO 63105.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$195

    Performed 1.5 hours of commercial labor for heating and air conditioning service.