HVAC Service Call — Refrigerant lines cut; AC coil needs replacing

  • HVAC

On May 26, 2026, ASSURED HEATING AND COOLING documented HVAC at 10432 Royal Drive, St. Louis, MO 63136.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$154

    Diagnosed no-AC call: refrigerant lines from indoor coil to outside condenser were cut and removed, other copper piped cut and piled on a tarp, and the AC coil will need replacement because the compressor ran with no refrigerant and was exposed to air and moisture.

  • HVACWork status not resolved

    Photograph shows a large collection of removed copper pipes and fittings of various sizes, some with dark insulation or tape wrapping, laid out on a tarp on a concrete floor.

  • HVACWork status not resolved

    Photograph shows a large pile of removed copper pipes, fittings, elbows, and insulated copper line sets laid out on a tarp on a concrete floor, along with a blue torch canister with handwritten markings.

  • HVACWork status not resolved

    Photograph shows the interior of an HVAC air handler or plenum cabinet with a heavily soiled fibrous liner/filter, significant debris accumulation, dark staining, a corroded or charred fitting/component resting on the filter media, yellow foam sealant in multiple locations, and a white electrical wire running along the top edge of the cabinet.

  • HVACWork status not resolved

    Photograph shows a black outdoor air conditioning condenser unit on the side of the house, heavily surrounded and partially obscured by overgrown weeds and shrubs growing up through and around the unit.

  • UnclassifiedWork status not resolved

    Photograph shows the side yard of a residential property with overgrown grass and weeds along the foundation, an asphalt driveway surface running alongside the house, white vinyl siding with a brick corner, a small side window, and a chain-link fence gate visible in the background.

  • HVACWork status not resolved
Record 2Public property record

HVAC Equipment Estimate — 2-ton 13.4 SEER2 condenser + TXV coil

  • HVAC

On May 26, 2026, ASSURED HEATING AND COOLING documented HVAC at 10432 Royal Drive, St. Louis, MO 63136.

Record date

Available findings

  • HVACEstimate or proposed work$5,868

    Estimate for Option #1: 2 Ton 13.4 SEER2 R454B W/TXV Coil (We propose to install the following equipment in your home), Terms and Conditions, Equipment Warranty, Payment Terms Net 30, 3/4 - 3/8 Line Set Up To 50ft (We will install new line set from indoor coil to outdoor condenser per code).

Record 3Public property record

HVAC Service Call — Ductwork needs repair; AC working as should

  • HVAC

On June 10, 2026, ASSURED HEATING AND COOLING documented HVAC at 10432 Royal Drive, St. Louis, MO 63136.

Record date

Available findings

  • HVACCompleted work

    Service call for new AC reported not working; ductwork appears to have been removed after install and needs repair, and the equipment was found to be working as it should be.

  • HVACWork status not resolved

    Photograph shows a crawl space or sub-floor area with wood floor joists framing against a concrete/masonry foundation wall; a small rectangular louvered foundation vent is mounted in the wall between framing members, with a concrete slab visible in the foreground.

  • HVACWork status not resolved

    Photograph shows basement HVAC ductwork with a visibly open gap and torn/peeling foil tape at the junction between a round metal duct and a rectangular sheet-metal plenum; rust and corrosion are also visible on the round duct.

  • HVACWork status not resolved

    Photograph shows a round metal duct visible within a narrow open cavity between a white finished wall and a wood-sheathed ceiling structure, with dark marks visible on the wood sheathing above.