- HVAC · New 2.5-ton HVAC system installed in apartment unit · Oct 2024
- HVAC · Condenser wiring corrected; AC ran properly after fix · May 2025
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 2 documented records for 10856 Verhaven Lane, St. Louis, MO 63114, dated from October 2024 through May 2025. The amount summary includes $6,122.12 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Replacement — Rheem furnace + 2-ton condenser install
- HVAC
Built from Housecall Pro data
- $6,122HVACWork performed: Apartment Full Install 2.5 Ton R410A 80% 50,000/75,000 BTU (We propose to install the follow equipment in listed unit); Equipment Warranty; Payment Terms Net 30/45; Terms and Conditions.
Documented warrantyfive-year / ten-year / twenty-yearFrom invoiceView details
What this warranty covers
- parts
· source
“All equipment installed by Contractor comes with a manufacturer five-year parts warranty”
- compressor
· source
“ten-year compressor warranty”
- parts
· source
“Once the equipment has been properly registered, the five-year manufacturer parts warranty becomes a ten-year parts warranty.”
- labor
· source
“Contractor offers a ten-year labor warranty on all new equipment installed by contractor.”
- heat exchanger
· source
“a twenty-year heat exchanger warranty”
Coverage based on an invoice. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC AC Check — Condenser wired to wrong unit's thermostat
- HVAC
Built from Housecall Pro data
- HVACAC check found the system not running in cool mode; the condenser's two-strand wiring was tied into Apt A's thermostat wiring, was corrected to the right unit, and the system then ran as intended with good pressures.
- HVACR-410A TXV system subcooling measured at 7° against a recommended 10°; app System Status indicates Correct Charge.
- HVACPhotograph shows a Fieldpiece SMAN Refrigerant Manifold + Micron Gauge connected to an HVAC system, displaying R-410A readings: low-side 115.2 psig (SH 13.5°F, VSAT 38.3°F), high-side 210.4 psig (SC 6.1°F, LSAT 88.7°F), with outdoor dry-bulb 84.7°F and suction line temp 51.8°F.
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this building.