← MAP

10856 Verhaven Lane

St. Louis, MO 6311438.6945°N, 90.4018°W
2Events
Contributed by:1 contributor
$6.1kDocumented amounts
SOURCE-BACKED RECORDS

Across 2 records on this building

Completed work

Invoices and paid receipts

$6.1k

Estimated · not confirmed

Quotes, estimates, and other amounts not confirmed as performed

None documented yet

Property History Report

Negotiate this home like you've seen its receipts. You have.

Free right now · built from this home's 2 documented records

Fresh House Property Summary

Highlights selected from 2 documented records for this property.

  • HVAC
    HVAC · New 2.5-ton HVAC system installed in apartment unit · Oct 2024
  • HVAC
    HVAC · Condenser wiring corrected; AC ran properly after fix · May 2025
Ask this homePowered by Fresh House property intelligence®
THE HOME

Hi, I'm 10856 Verhaven Lane. I only speak from this property's source-backed records — 2 documents from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.

ASK ME ABOUT

RECORD SUMMARY

2 documented events
Contributed by: 1 contributor
First documented event: Oct 2024
Latest documented event: May 2025
First added to Fresh House: Nov 2026
Fresh House

Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.

DOCUMENTED HISTORY

This page contains 2 documented records for 10856 Verhaven Lane, St. Louis, MO 63114, dated from October 2024 through May 2025. The amount summary includes $6,122.12 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.

HVAC

HVAC Replacement — Rheem furnace + 2-ton condenser install

Document dated Oct 24, 2024Uploaded Nov 10, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 10856 Verhaven Lane, St. Louis, MO 63114.
Scope
  • HVAC
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $6,122
  • HVACWork performed: Apartment Full Install 2.5 Ton R410A 80% 50,000/75,000 BTU (We propose to install the follow equipment in listed unit); Equipment Warranty; Payment Terms Net 30/45; Terms and Conditions.
    $6,122
warrantyfive-year / ten-year / twenty-yearFrom invoiceView details
Documented warrantyfrom invoice · Oct 24, 2024HVAC · 5 terms

What this warranty covers

five-year
  • parts
    · source

    “All equipment installed by Contractor comes with a manufacturer five-year parts warranty”

ten-year
  • compressor
    · source

    “ten-year compressor warranty”

  • parts
    · source

    “Once the equipment has been properly registered, the five-year manufacturer parts warranty becomes a ten-year parts warranty.”

  • labor
    · source

    “Contractor offers a ten-year labor warranty on all new equipment installed by contractor.”

twenty-year
  • heat exchanger
    · source

    “a twenty-year heat exchanger warranty”

Coverage based on an invoice. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC AC Check — Condenser wired to wrong unit's thermostat

Document dated May 16, 2025Uploaded Nov 10, 20263 files
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 10856 Verhaven Lane, St. Louis, MO 63114.
Scope
  • HVAC
Contributor
worked on or inspected it

Built from Housecall Pro data

  • HVACAC check found the system not running in cool mode; the condenser's two-strand wiring was tied into Apt A's thermostat wiring, was corrected to the right unit, and the system then ran as intended with good pressures.
  • HVACR-410A TXV system subcooling measured at 7° against a recommended 10°; app System Status indicates Correct Charge.
  • HVACPhotograph shows a Fieldpiece SMAN Refrigerant Manifold + Micron Gauge connected to an HVAC system, displaying R-410A readings: low-side 115.2 psig (SH 13.5°F, VSAT 38.3°F), high-side 210.4 psig (SC 6.1°F, LSAT 88.7°F), with outdoor dry-bulb 84.7°F and suction line temp 51.8°F.
Attached photo 1HVAC
Attached photo 2HVAC

Only original contributor can modify this entry

Create an account to manage your contributions over time

Only the original contributor can modify this entry · Create an account to manage your contributions over time.

Add inspections, repairs, appraisals,
or anything that shaped this building.

PROPERTY COVERAGE

HVAC
✓ documented
Home Inspection
undocumented
Roof
undocumented
Plumbing
undocumented
Sewer
undocumented
Foundation
undocumented
Mold
undocumented
Electrical
undocumented
Pest
undocumented
Radon
undocumented
Appraisals
undocumented
Windows
undocumented

Nearby homes with documented history