Hi, I'm 110 Shawnee Lane. I only speak from this property's source-backed records — 4 documents from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.
110 Shawnee Lane
Across 4 records on this home
Completed work
Invoices and paid receipts
Estimated · not confirmed
Quotes, estimates, and other amounts not confirmed as performed
Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 4 documented records
Fresh House Property Summary
Highlights selected from 4 documented records for this property.
- HVAC · Evaporator coil replaced and blower cleaned on central AC · Aug 2025
- HVAC · Gas lines replaced and ductwork insulation repaired · Aug 2025
- HVAC · AC wiring short traced and repaired; compressor found failed · May 2026
- HVAC · Full AC condensing unit replacement estimated but not confirmed · May 2026$6.2k
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 4 documented records for 110 Shawnee Lane, Florissant, MO 63033, dated from August 2025 through May 2026. The amount summary includes $4,856.54 in completed work across HVAC, $6,160 in estimates; appraisal values and permit-declared valuations are excluded.
HVAC Service Call — Gas line union in cabinet, fire hazard
- HVAC
Built from Housecall Pro data
- $154HVACService call and half hour of labor for central air blowing warm air; found blower motor filled with debris and wrong size coil, and a gas line union inside the cabinet noted as a fire hazard needing correction.
- HVACPhotograph shows an outdoor air conditioning condenser unit installed on a pad adjacent to the home's foundation wall, with refrigerant lines entering the building through the foundation; the surrounding ground is bare dirt covered with fallen leaves.
- HVACPhotograph shows a metal furnace flue/exhaust vent pipe with a 90-degree elbow at the top, screwed sectional joints, and heavy white mineral deposit or scale buildup coating the lower section of the pipe where it exits the furnace cabinet base; foil tape is visible at the pipe base.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Coil Replacement — Coil replacement, blower clean, gas line redo
- HVAC
Built from Housecall Pro data
- $4,275HVACPulled and cleaned blower, replaced 14" coil with piston 17" 2.5 ton coil, repaired insulation and ductwork, removed and replaced gas lines to code, and supplied 4 lbs R410A refrigerant.
- HVACPhotograph shows a large centrifugal (squirrel-cage) blower wheel removed from an HVAC unit, with blades heavily coated in dust and debris; a cordless drill and tool bag are visible nearby indicating active service work.
- HVACliquid pressure 342.3 Psig, subcooling 6.5°F, LSAT 105.0°F outdoor dry bulb 85.3°F, suction line temp 57.4°F, liquid line temp 98.5°F
- HVACfloor around the unit shows staining and debris
- HVACPhotograph shows a hand holding an orange flashlight probing a gap at the base of a large metal furnace or boiler unit; visible conditions include heavy rust staining on the surrounding concrete surface and soot or burn discoloration on the metal housing above the gap.
- HVACPhotograph shows an orange digital thermometer probe inserted into a sheet metal HVAC supply duct, with the display reading approximately 126°F, in what appears to be a basement mechanical room with additional ductwork and piping visible.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Repair Invoice — Compressor windings open; AC needs replacing
- HVAC
Built from Housecall Pro data
- $428HVACTraced a short in the 2-strand whip from disconnect to AC, replaced the wire and the blown fuse on the furnace board; compressor windings tested open, so the AC will need to be replaced.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Replacement Estimate — 2.5-ton 13.4 SEER2 condenser + coil
- HVAC
Option: Option #1 $6,160 (declined)
Built from Housecall Pro data
- $6,160HVACEstimate for Option #1: 2.5 Ton 13.4 SEER2 R454B W/TXV Coil (We propose to install the following equipment in your home), Terms and Conditions, Coil/Condensing Unit Install Description (This quote includes, fused disconnect, electrical whip and pad for condensing), Payment Terms, Equipment Warranty.
Documented warrantyfive-year / ten-year / twenty-yearFrom estimateView details
What this warranty covers
- parts
· source
“manufacturer five-year parts warranty”
- compressor
· source
“ten-year compressor warranty”
- parts
· source
“Once the equipment has been properly registered, the five-year manufacturer parts warranty becomes a ten-year parts warranty.”
- labor
· source
“Contractor offers a ten-year labor warranty on all new equipment installed by contractor.”
- heat exchanger
· source
“a twenty-year heat exchanger warranty”
Coverage based on an estimate. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.
Only original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,