HVAC Seasonal Maintenance — System won't start; board terminals
- HVAC
On November 10, 2025, ASSURED HEATING AND COOLING documented HVAC at 11039 Landseer Drive, St. Louis, MO 63136.
- Record date
Available findings
- HVACCompleted work
Seasonal maintenance visit: system would not start on arrival; two low-voltage terminals missing on the board and a twinning fault code shown though not a twin system; replacement recommended.
- HVACWork status not resolved
Photograph shows the open interior of a gas furnace with extensive rust and corrosion on the sheet metal cabinet walls and frame, a draft inducer motor, pressure switches with rubber hoses, a gas valve, control board, and wiring harness; heavy dust and debris accumulation is visible throughout the cabinet.
- HVACWork status not resolved