Complete public upload archive

Property records for 11068 Golf Crest Drive, St. Louis, MO 63126

All 2 public upload records returned by the Fresh House property feed are available across 1 server-rendered page. This page shows records 1 to 2.

Record details are source-backed where available. Permit status and descriptions repeat the publishing agency's data; they do not independently establish that work was completed.

Return to the property overview
Record 1Public property record

HVAC Diagnostic Service — Diagnostic visit, Eaton 15 amp breaker

  • HVAC

On November 9, 2025, JLM HEATING AND AIR CONDITIONING documented HVAC at 11068 Golf Crest Drive, St. Louis, MO 63126.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$280

    Diagnostic trip and 1.5 hours of labor performed, with an Eaton 15 amp single pole breaker supplied.

Record 2Public property record

HVAC Diagnostic Service — Overtime diagnostic and 2 hours labor

  • HVAC

On February 21, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 11068 Golf Crest Drive, St. Louis, MO 63126.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$540

    Performed an overtime residential diagnostic and two units of overtime residential labor.

  • HVACWork status not resolved

    Photograph shows an HVAC furnace/air handler unit with access panel open and a 16x25x1 air filter (actual size 15-11/16 x 24-11/16 x 25/32 in) positioned at the filter slot.

  • HVACWork status not resolved

    Photograph shows an open residential electrical panel with multiple circuit breakers (15A, 20A, and 30A), with several loose and unsecured wires visible on the left side of the enclosure.

  • HVACWork status not resolved

    Photograph shows the interior of an open gas furnace with the access panel removed, revealing an active multi-port burner assembly with blue flames, a draft inducer motor at the top, gas valve/manifold, wiring harnesses, and a control board at the bottom.

  • HVACWork status not resolved

    yellow fiberglass insulation is visible adjacent to the unit

  • HVACWork status not resolved

    Photograph shows the interior of an electrical panel with visible burn and char damage on the bus bar and adjacent breaker position, with scorched and melted material present; multiple 100A and 20A breakers are visible.

  • HVACWork status not resolved
  • HVACWork status not resolved

    Photograph shows a technician using a Klein Tools clamp meter (displaying approximately 7.125) with test probes applied to wiring inside an open HVAC air handler or furnace panel; multiple wires and a circuit board are visible inside the cabinet.

View 11068 Golf Crest Drive, St. Louis, MO 63126 on Fresh House