11136 Cadigan Drive
Across 2 records on this home
Completed work
Invoices and paid receipts
Estimated · not confirmed
Quotes, estimates, and other amounts not confirmed as performed
Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 2 documented records
Fresh House Property Summary
Highlights selected from 2 documented records for this property.
- HVAC · Gas furnace replaced with new American Standard unit · Aug 2026
- HVAC · Furnace installation included new flue pipe and filter rack · Aug 2026
- HVAC · Service trip to basement HVAC unit was billed · Jul 2026
- HVAC · Tenant reported loud vibrating noise from basement HVAC unit · Jul 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 2 documented records for 11136 Cadigan Drive, St. Louis, MO 63138. The amount summary includes $4,732.20 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Service Trip Invoice — HVAC service trip fee
- HVAC
Built from Housecall Pro data
- $145HVACWork performed: Trip Fee.
- HVACPhotograph shows a Category I forced air furnace data plate: model GUJ100D12-1A, serial 8493M33399, 100,000 BTU/HR input, 80,000 BTU/HR output, natural gas, 115V 1PH 60HZ.
- HVACPhotograph shows an aged gas furnace in a basement with the front access panel removed, exposing the blower motor, burner assembly, and internal components; metal flue pipes rise from the unit to the plenum above; unit appears heavily dusty and worn.
- HVACPhotograph shows galvanized sheet-metal flue ductwork connecting to the water heater and running vertically, exhibiting visible corrosion, rust staining, and deterioration at joints.
- HVACTenant reported indoor HVAC unit in basement making a loud vibrating noise described as sounding like a helicopter; outdoor condenser unit is operating normally.
- HVACPhotograph shows an older gas forced-air furnace in a basement with the front access panel open or removed, exposing the blower motor and internal components
- HVACPhotograph shows a round metal flue or exhaust duct pipe with heavy rust and corrosion concentrated at the seams and elbow joint, connecting to a rectangular sheet metal plenum or duct in what appears to be a basement mechanical area.
- HVACPhotograph shows a gray metal air handler unit installed in a mechanical space, connected to sheet metal ductwork above, copper refrigerant lines on the right side, a white flexible line, and a black drain line exiting at the bottom; staining is visible on surrounding ductwork and walls.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Installation — American Standard S8X1 80k gas furnace
- HVAC
Built from Housecall Pro data
- $4,587HVACFurnace work with an American Standard Silver S8X1 80,000 BTU gas furnace, journeyman and apprentice labor, install materials, a 1" external filter rack, and flue pipe with elbows.
- $4,587HVAC
- HVACPhotograph shows a gray upflow gas furnace with a metal flue pipe and large sheet metal supply plenum, connected by black iron gas supply piping; a yellow service tag is affixed to the unit.
- HVACPhotograph shows a UEI EM152 digital manometer connected to a furnace reading 3.52 inH2O, with a water heater and gas supply piping visible in the background.
- HVACPhotograph shows a close-up view of an outdoor air conditioning condenser unit with a dark gray louvered metal cabinet; condenser coil fins are visible through the grille openings and appear intact with no obvious damage visible from this angle.
- HVACPhotograph shows a UEI PDT650 pocket thermometer displaying a reading of 82.5°F, placed against a corrugated galvanized metal surface consistent with HVAC ductwork.
- HVACPhotograph shows an outdoor HVAC condenser unit with fins heavily packed with dirt, dust, and fibrous debris, substantially restricting airflow through the coil; a partial red service sticker is visible on the unit casing.
- HVACPhotograph shows a UEI handheld digital thermometer displaying a reading of 63.5°F, resting on a gray speckled surface.
- HVACPhotograph shows a technician holding a yellow digital manometer connected to an HVAC air handler cabinet, displaying dual pressure readings of 0.13 inWC and 0.33 on its LCD screen, with multiple wiring harnesses and tubing visible inside the unit and accumulated dust/debris present.
Documented warranty1-year / 5-yearFrom estimateView details
What this warranty covers
- 1-year parts and labor warranty
- 5-year manufacturer warranty (non-owner occupied)
Coverage based on an estimate. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.