1115 Grandview Drive
Across 1 record on this home
Completed work
Invoices and paid receipts
Estimated · not confirmed
Quotes, estimates, and other amounts not confirmed as performed
Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 1 documented records
Fresh House Property Summary
Highlights selected from 1 documented record for this property.
- HVAC · AC diagnostic performed and refrigerant added · Aug 2026
- HVAC · Resident reported AC not cooling and thermostats not working · 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 1 documented record for 1115 Grandview Drive, Kirkwood, MO 63122, dated in August 2026. The amount summary includes $555 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Diagnostic and Refrigerant Service — Diagnostic and 410-A
- HVAC
Built from Housecall Pro data
- $555HVACPerformed a residential OT diagnostic and added 410-A refrigerant (3lb max).
- HVACPhotograph shows a Fieldpiece app Refrigerant Side measurement screen for R-410A: suction pressure 122.9 psig, liquid pressure 333.8 psig, suction temperature 58.4°F, liquid temperature 95.1°F, vapor saturation 41.9°F, liquid saturation 103.3°F, actual superheat 16.5°F, actual subcooling 8.2°F, and discharge pressure 333.8 psig.
- HVACPhotograph shows a dual run capacitor (model 20350440CS, rated 20+35 μF at 440VAC, 50/60Hz) installed inside an HVAC cabinet, with red, purple, brown, and yellow wires connected to its terminals.
- HVACPhotograph shows the open wiring compartment of an outdoor HVAC condensing unit with multiple multi-colored wires bundled and routed to a contactor; two blue wire nuts are visible joining wires mid-run, and a white cable tie secures the wire harness.
- HVACPhotograph shows a cylindrical run capacitor mounted inside an HVAC cabinet, with yellow, purple, brown, and red wires connected to its terminals.
- HVACPhotograph shows large round and rectangular galvanized sheet-metal HVAC ductwork running horizontally across the ceiling of an unfinished basement, with a handwritten notation '2nd floor' visible on the ductwork.
- HVACPhotograph shows a basement mechanical room with a furnace/air handler unit, extensive sheet metal supply plenum and branch ductwork suspended from ceiling joists, with visible foil tape repairs and multiple wiring runs along the ducts; red and green indicator lights are visible on equipment.
- HVACResident reports air conditioner not cooling; main level thermostat not working and upstairs thermostat keeps resetting to 85 after power outage. Probable diagnosis: AC closed ventilation.
- HVACPhotograph shows an outdoor air conditioning condenser unit on a concrete pad against a brick wall, heavily surrounded by overgrown vegetation on multiple sides; a box of Honeywell Genetron AZ-20 410A refrigerant is visible in the foreground.
- HVACPhotograph shows large rectangular sheet metal supply ductwork and a flexible round branch duct running along the basement ceiling, with what appears to be an HVAC component or control device mounted to the ductwork.
- HVACPhotograph shows metal HVAC ductwork in a crawlspace with two motorized zone damper actuators mounted on separate ducts; the upper actuator displays a green LED indicator and the lower actuator displays a red LED indicator, with multiple wiring connections visible nearby.
- HVACFieldpiece app measurement shows R-410A system with suction pressure 122.7 psig, liquid pressure 326.9 psig, actual superheat 18.0°F, and actual subcooling 3.2°F.
- HVACPhotograph shows an open electrical control board enclosure with a multi-terminal green PCB (pink LED active) and a white 'PRO' branded device with green status LEDs, both mounted to the underside of floor framing in an unfinished basement; multiple wires run from the board.
- HVACPhotograph shows a basement furnace unit with a sheet metal supply plenum and branch round ducts connected above, foil-taped duct joints, flexible gas or electrical conduit, and a service company sticker affixed to the furnace cabinet; wiring runs along exposed floor joists overhead.
- HVACPhotograph shows an outdoor air conditioning condenser unit heavily encroached upon by dense, overgrown vegetation on all sides, with plants growing directly against and over the unit's coil fins and fan grille.
- HVACPhotograph shows large-diameter sheet metal supply trunk duct and multiple branch ducts with elbow transitions suspended from floor joists in an unfinished basement, with several small electronic zone damper actuators (displaying red and green LED indicator lights) mounted at duct junctions.
- HVACPhotograph shows a dark-colored furnace unit with sheet metal supply ductwork and a flexible metal exhaust flue running overhead in an unfinished basement; ductwork appears intact with no visible damage.
- HVACservice stickers are visible on the air handler cabinet
- HVACPhotograph shows exposed round and rectangular sheet-metal ductwork running along the unfinished basement ceiling, with multiple duct elbows and transitions visible, along with a small electronic control panel or device mounted near the ductwork junction.
- HVACPhotograph shows a 6-inch round metal duct with a zone damper actuator (labeled '6" URD' and '1st FLR') mounted in a basement mechanical space; the actuator's red LED indicator is illuminated and an HVAC unit with a green LED is visible above.
- HVACPhotograph shows a multi-conductor cable with severely cracked, split, and deteriorated outer insulation, exposing inner conductors; a visible electrical safety hazard within what appears to be HVAC equipment wiring.
- HVAC · document contextPhotograph shows an unfinished basement with exposed overhead floor joists painted dark, black ABS/cast-iron drain pipes and white PVC pipes running along the ceiling, HVAC ductwork, a steel support column, painted concrete block walls, a bare concrete floor, and miscellaneous stored household items including bins, shelving, holiday decorations, and coolers.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.