Hi, I'm 11840 Sologne Court. I only speak from this property's source-backed records — 1 document from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.
11840 Sologne Court
Across 1 record on this home
Completed work
Invoices and paid receipts
Estimated · not confirmed
Quotes, estimates, and other amounts not confirmed as performed
Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 1 documented records
Fresh House Property Summary
Highlights selected from 1 documented record for this property.
- HVAC · AC and air handler replacement estimated but not confirmed done · Jul 2026$8.7k
- HVAC · Existing outdoor AC unit manufactured in October 2014 · 2026
- HVAC · Air handler unit visible in basement with duct connections and refrigerant lines · 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 1 documented record for 11840 Sologne Court, Maryland Heights, MO 63043, dated in July 2026. The amount summary includes $8,653 in estimates; appraisal values and permit-declared valuations are excluded.
HVAC Replacement Estimate — 2-ton AC & air handler, 10kW heat option
- HVAC
Options: 2-ton 14 SEER AC & Air Handler (HE) 10kW Heat $8,957.50 (expired) · Option #2 (canceled) · 2-ton 13 SEER Goodman System $8,653 (expired)
Built from Housecall Pro data
- $8,653HVACEstimate for replacement of the AC and air handler with a 10kW heat kit, thermostat, disconnect and install materials, with an alternate Goodman system option; no options approved.
- HVACPhotograph shows the manufacturer data plate on a Rheem outdoor condenser unit, model 13AJN24A01, serial W411428146, manufactured 10/2014, rated 208/230V single-phase, R-410A refrigerant, factory charge 67.8 oz.
- HVACPhotograph shows a vertical HVAC air handler unit in a basement utility space with sheet metal plenum and ductwork above; foil tape at duct connections appears aged and partially separated, and a dark debris accumulation is visible at a pipe connection on the left side of the cabinet.
- HVACPhotograph shows a vertical HVAC air handler unit connected to a sheet metal plenum with foil tape that appears wrinkled and partially separated at joints; refrigerant line insulation at an elbow fitting is visibly deteriorated or missing; a condensate drain line exits the lower cabinet section.
- HVACA24-10, Serial No. 9602037853, rated 208/240V 1PH 60Hz with a single circuit ampacity of 35.3/40.8A and a max fuse/breaker of 50/60A a Filtrete filter is visible at the right edge of the cabinet
- HVACPhotograph shows a large gray sheet-metal supply duct running along the upper ceiling and a flexible silver exhaust duct visible on the left wall of the basement utility space.
- HVACPhotograph shows multiple cables and conduits; including a white Cat-5e data cable, several black cables, and a blue conduit; bundled and routed along a ceiling/wall junction, secured with clips or zip ties.
- HVACa Filtrete filter is visible at the right edge of the cabinet
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.