1205 South 5th Street
Across 5 records on this property
Completed work
Invoices and paid receipts
Estimated · not confirmed
Quotes, estimates, and other amounts not confirmed as performed
Fresh House Property Summary
Highlights selected from 5 documented records for this property.
- HVAC · Large rooftop gas package unit installed with fresh air and ductwork · Dec 2024$20k
- HVAC · Code-required smoke detector installed with new rooftop unit · Dec 2024
- HVAC · Control board and transformer replaced after damage from misinstalled screw · Jul 2025
- HVAC · Older system showed signs of heat exchanger damage; replacement recommended · Dec 2024
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 5 documented records for 1205 South 5th Street, Saint Charles, MO 63301, dated from December 2024 through July 2025. The amount summary includes $21,346.33 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Repair — Replaced control board, transformer, smoke detector
- HVAC
Built from Housecall Pro data
- $1,020HVACFound outdoor unit with shorted transformer and control board caused by an improperly installed screw from other ductwork; replaced the smoke detector, fixed the wiring, and replaced the control board and transformer under manufacturers parts warranty.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — Failing heat exchanger; replacement advised
- HVAC
Built from Housecall Pro data
- $194HVACService call found the system functioning as intended but showing signs of a damaged or failing heat exchanger; system is eleven almost twelve years old and replacement was recommended.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Ductwork — 7.5-ton gas package unit installed
- HVAC
Built from Housecall Pro data
- $20,133HVACFurnished and installed a 7.5 ton Rheem gas package unit with manual fresh air, re-insulated rooftop ductwork, and installed a smoke detector required by code for units 5 tons and up.
Documented warrantyfive-year / ten-year / twenty-yearFrom invoiceView details
What this warranty covers
- parts
· source
“manufacturer five-year parts warranty”
- compressor
· source
“ten-year compressor warranty”
- parts
· source
“Once the equipment has been properly registered, the five-year manufacturer parts warranty becomes a ten-year parts warranty.”
- labor
· source
“Contractor offers a ten-year labor warranty on all new equipment installed by contractor.”
- heat exchanger
· source
“a twenty-year heat exchanger warranty”
Coverage based on an invoice. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Invoice — No-charge service visit, no lines itemized
- HVAC
Built from Housecall Pro data
- HVACInvoice for a service visit on March 17, 2025 with no service lines itemized.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Invoice — No-charge service visit
- HVAC
Built from Housecall Pro data
Only original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this property.