- HVAC · Furnace replaced and new coil installed · Feb 2023
- HVAC · Evaporator coil replaced · Aug 2024
- HVAC · Full HVAC system replaced due to refrigerant leak · Apr 2024
- HVAC · Furnace found producing carbon monoxide in heat mode · Dec 2023
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 11 documented records for 1211 Tuxford Drive, St. Louis, MO 63146, dated from July 2022 through August 2024. The amount summary includes $21,151.76 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Refrigerant Service — Recovered ~1.5 lbs R22 from overcharged
- HVAC
Built from Housecall Pro data
- $94HVACFound unit overcharged for current conditions, recovered approximately 1.5 lbs of R22, let system balance and monitored it; system working as intended at completion (labor only).
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC No-Cooling Service Call — Bad control board and blower
- HVAC
Built from Housecall Pro data
- HVACService call for no AC: found the control board and blower bad due to age and condition of the furnace, replacement recommended; AC verified to come on but would need R22 added.
- HVACPhotograph shows an outdoor HVAC unit at lower right with gray flexible conduit and a white PVC pipe (likely a condensate drain or line set cover) running along a brick exterior wall, with black foam insulation material visible at the top connection point and dead leaf debris on the ground.
- HVACPhotograph shows the interior of an outdoor HVAC condenser unit viewed through the wire grille, with visible fan motor assembly, copper refrigerant lines, a small multi-wire electrical connector/sensor, and significant accumulation of dried leaves and organic debris on the unit base.
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Furnace Replacement — 80% 75,000 BTU furnace installed
- HVAC
Built from Housecall Pro data
- $2,941HVACWork performed: TX1110 (Current Furnace Is 10-15 years old and missing lots of parts and in rough place); 80% Furnace Only - 80% 75,000 BTU Furnace (We purpose to install the following equipment in your home); Oxford, Description - Furnace Only (This quote will include the following, sheet metal work to adapt to new); Oxford, Description - Warranty (All equipment installed comes with a 5 year parts warranty, 10 year compressor); Oxford, Description - Payment Terms (All excepted quotes are Net 30/45 upon completion date).
Documented warranty5 year / 10 year / 20 yearFrom invoiceView details
What this warranty covers
- parts
· source
“All equipment installed comes with a 5 year parts warranty”
- compressor
· source
“10 year compressor warranty”
- parts/compressor
· source
“Once equipment is registered this will become 10 year parts/compressor warranty”
- heat exchanger
· source
“20 year heat exchanger warranty”
Coverage based on an invoice. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — No AC; control board needed, blower hard wired
- HVAC
Built from Housecall Pro data
- $50HVACNo AC, needs new control board; blower was hard wired to keep tenants comfortable until the control board can be replaced.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Control Board Replacement — Control board replaced
- HVAC
Built from Housecall Pro data
- $472HVACReplaced control board.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Furnace Replacement — 80% gas furnace and coil install
- HVAC
Built from Housecall Pro data
- $3,591HVACWork performed: TX1103/ WTN- 63603302; Oxford, Furnace 80%/Coil Piston - Furnace/Coil Cased and Uncased 50,000/75,000 BTU (We propose to install the following equipment in above listed unit); Install Desc - Furnace/Coil Only Install Description (This quote will include the following, sheet metal work to adapt to new); Oxford, Description - Warranty (All equipment installed comes with a 5 year parts warranty, 10 year compressor); Oxford, Description - Payment Terms (All excepted quotes are Net 30/45 upon completion date).
Documented warranty5 year / 10 year / 20 yearFrom invoiceView details
What this warranty covers
- parts
· source
“All equipment installed comes with a 5 year parts warranty”
- compressor
· source
“10 year compressor warranty”
- parts/compressor
· source
“Once equipment is registered this will become 10 year parts/compressor warranty”
- heat exchanger
· source
“20 year heat exchanger warranty”
Coverage based on an invoice. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Furnace Replacement — 80% gas furnace replacement, 50-75k BTU
- HVAC
Built from Housecall Pro data
- $3,367HVACWork performed: TX11-6 / P.O 1965080 (Furnace only replacement); Furnace Only 50,000/75,000 BTU 80% - 80% Furnace Only 50,000/75,000 BTU (We propose to install the following equipment in listed unit); Install Desc - Equipment Warranty (Equipment Warranty); Apartment, Description - Payment Terms Net 30/45; Install Desc - Terms and Conditions.
Documented warrantyfive-year / ten-year / twenty-yearFrom invoiceView details
What this warranty covers
- parts
· source
“manufacturer five-year parts warranty”
- labor
· source
“Contractor offers a five-year labor warranty on all new equipment installed by contractor.”
- compressor
· source
“ten-year compressor warranty”
- parts
· source
“Once the equipment has been properly registered, the five-year manufacturer parts warranty becomes a ten-year parts warranty.”
- heat exchanger
· source
“a twenty-year heat exchanger warranty”
Coverage based on an invoice. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Work — Rewired control wires; A/C and heat working
- HVAC
Built from Housecall Pro data
- $100HVACRewired control wires and system is running as intended in ac and heat mode.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Furnace Replacement — Cracked heat exchanger, CO at 230 ppm
- HVAC
Built from Housecall Pro data
- $3,013HVACWork performed: 80% Furnace Only (We propose to install the following equipment in listed unit); Payment Terms Net 30/45; Terms and Conditions; Description (After starting unit in heat mode system is putting off carbon monoxide reached).
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Replacement — 2-ton condenser + 80% furnace replacement
- HVAC
Built from Housecall Pro data
- $5,924HVACWork performed: TX11-1 / P.O 2129820 (Current system is empty on refrigerant and leak in not in a repairable spot); Apartment Full Install 2 Ton R410A 80% 50,000/75,000 BTU (We propose to install the follow equipment in listed unit); Warranty (Equipment Warranty); Payment Terms Net 30/45; Terms and Conditions.
Documented warrantyfive-year / ten-year / twenty-yearFrom invoiceView details
What this warranty covers
- parts
· source
“All equipment installed by Contractor comes with a manufacturer five-year parts warranty”
- labor
· source
“Contractor offers a five-year labor warranty on all new equipment installed by contractor.”
- compressor
· source
“ten-year compressor warranty”
- parts
· source
“Once the equipment has been properly registered, the five-year manufacturer parts warranty becomes a ten-year parts warranty.”
- heat exchanger
· source
“a twenty-year heat exchanger warranty”
Coverage based on an invoice. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Coil Replacement — Coil replaced
- HVAC
Built from Housecall Pro data
- $1,600HVACReplaced coil at 1211 Tuxford Drive.
Only original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.