Record 1Public property record

HVAC Diagnostic Service — Commercial diagnostic service

  • HVAC

On June 1, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 12139 Manchester Road, St. Louis, MO 63131.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$140

    Performed a commercial diagnostic service.

  • HVACWork status not resolved

    Photograph shows a pleated HVAC air filter in its housing with visibly gray, dust-laden filter media; a second heavily soiled filter is partially visible behind it, suggesting the filter(s) are due for replacement.

  • HVACWork status not resolved

    Photograph shows the base of a rooftop HVAC unit with a white PVC condensate drain pipe exiting the unit and running along the flat roof surface; dark staining is visible on the roof membrane near the unit base.

  • HVACWork status not resolved

    Photograph shows large-diameter white PVC radon mitigation piping with sweep elbows routed overhead in a crawl space or basement, above a cracked and separated sub-slab aggregate/granular surface and black poly vapor barrier sheeting; white wall liner panels are visible along the perimeter walls.

  • HVACWork status not resolved

    Photograph shows a 20x25x2 ACM brand air filter installed in an HVAC air handler, with a handwritten date of '7/25' marked on the filter frame.

Record 2Public property record

HVAC Service Invoice — Return air modification, 4-RTU filter change

  • HVAC

On June 3, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 12139 Manchester Road, St. Louis, MO 63131.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$900

    Performed a return air modification and a building filter change on 4 rooftop units.

  • HVACWork status not resolved

    Photograph shows a white wall-mounted return air grille with horizontal louvers secured by four screws; surrounding wall surface shows scuffing and minor damage near the upper-right corner of the vent.

  • HVACWork status not resolved

    Photograph shows a white louvered return air grille mounted on a partially patched drywall wall, adjacent to sheet metal ductwork, with black iron pipes running overhead and red ambient lighting from below.

  • HVACWork status not resolved

    Photograph shows a large square egg-crate return air grille mounted in a drop ceiling, with visible dust and debris accumulation concentrated on the upper-left portion of the grille face; a recessed downlight is visible adjacent to the grille.

  • HVACWork status not resolved

    Photograph shows a large square egg-crate return air grille mounted in a suspended ceiling grid, with visible dust and debris accumulation concentrated in the upper-left portion of the grille; a small recessed light fixture is also visible adjacent to the grille.

  • HVACWork status not resolved

    all four filters appear heavily loaded with dust and particulate matter, indicating they are due for replacement

  • HVACWork status not resolved

    Photograph shows a large egg-crate style ceiling HVAC diffuser/grille mounted in a drop ceiling tile, flanked by two recessed can lights, with a sprinkler head visible in an adjacent ceiling tile, located near an illuminated EXIT sign above a doorway.

  • HVACWork status not resolved

    Photograph shows a wall-mounted louvered HVAC register with a thin wire or cable running vertically from overhead piping/framing down to the register face; white pipes and metal framing are visible near the ceiling above.

  • HVACWork status not resolved

    Photograph shows a square egg-crate style HVAC grille installed in a suspended drop ceiling grid within a commercial/retail interior space.

  • HVACWork status not resolved

    Photograph shows a large white perforated HVAC ceiling grille (approximately 2x2 ft) installed in a suspended drop-ceiling grid within what appears to be a commercial or clinical interior room; a recessed downlight is also visible in the ceiling.

  • HVACWork status not resolved

    two appear new/clean with white media and two show significant dust and dirt accumulation with black gasket frames

  • HVACWork status not resolved

    Photograph shows a large white round HVAC duct running diagonally near the ceiling, a smaller round duct fitting near the base of the wall, and a white louvered wall register.

  • HVACWork status not resolved
  • HVACWork status not resolved

    Photograph shows a large egg-crate (louvered grid) return air grille installed in a suspended drop ceiling with acoustic tile panels; no visible damage, obstruction, or discoloration noted on the grille or surrounding ceiling tiles.

Record 3Public property record

HVAC Commercial Service Call — Commercial trip, labor and overtime

  • HVAC

On August 8, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 12139 Manchester Road, St. Louis, MO 63131.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$650

    Commercial service call performed, including a trip fee, commercial labor, and two units of commercial overtime labor.

  • HVACWork status not resolved

    Photograph shows a large rooftop HVAC condenser/package unit with louvered side panels and top-discharge fan in the foreground, a disconnect box mounted to its side, refrigerant and electrical conduit lines running along the flat roof surface, and a second rooftop HVAC unit visible in the background; dark staining is visible on the roof membrane around the base of the foreground unit and corrosion is present on the foreground conduit.

  • HVACWork status not resolved

    Photograph shows a circular pipe opening set into a metal surface with heavy black and brown corrosion/buildup coating the interior pipe walls, surrounded by peeling paint, rust staining, and mineral deposits on the exterior metal surface below the opening.

  • HVACWork status not resolved

    additional rooftop HVAC units are visible in the background

  • HVACWork status not resolved

    Photograph shows a close-up of a corrugated metal furnace heat exchanger with visible rust, corrosion, and what appears to be a crack or rust breach at the seam of the heat exchanger tube.

  • HVACWork status not resolved

    Photograph shows multiple parallel heat exchanger tubes inside a furnace compartment with visible rust spots, brown discoloration, and corrosion along the tube seams and surfaces.

  • HVACWork status not resolved

    Photograph shows two metal tubes inside an HVAC unit interior with heavy dust accumulation and visible rust/corrosion staining, particularly on the lower tube and surrounding metal panels.

  • HVACWork status not resolved

    Photograph shows a white roofing membrane with multiple small holes/punctures, brown staining around the penetrations, visible wrinkling and bunching of the membrane surface, and a black circular roof drain fitting.

  • HVACWork status not resolved

    Photograph shows the base curb of an HVAC unit with a large-diameter copper refrigerant line, electrical wiring, mounting brackets, and dark staining/debris along the bottom edge of the galvanized steel curb frame; the surface below shows cracking and deterioration.

  • HVACWork status not resolved

    Photograph shows a commercial rooftop packaged HVAC unit with its left access panel open, exposing the internal coil assembly; additional rooftop units are visible in the background, and refrigerant/condensate piping runs beneath the unit curb.

  • HVACWork status not resolved

    Photograph shows a rooftop HVAC unit with a braided flexible condensate drain hose exiting the unit base and looping loosely on the roof surface, apparently disconnected from the nearby white PVC condensate drain standpipe; dark moisture staining is visible on the roof membrane around the unit base.

  • HVACWork status not resolved

    Photograph shows large sheet-metal ductwork with visible surface rust streaks, mineral/calcium deposits along seams, and accumulated grime; foil-faced insulation board is visible in the background.

  • HVACWork status not resolved

    Photograph shows a circular pipe opening set into a concrete or metal surface, with heavy dark corrosion, mineral/debris buildup coating the interior walls, and surrounding surface exhibiting peeling paint or coating, rust staining, and discoloration below the pipe.

  • HVACWork status not resolved

    Photograph shows a commercial flat roof with a two-tone membrane surface — a lighter gravel-surfaced section adjacent to a darker, aged/worn section — with dark staining visible on the roof surface near the base of an HVAC unit's condensate drain pipe.

  • HVACWork status not resolved

    Photograph shows the interior of a pipe with heavy dark buildup, corrosion, and deterioration coating the pipe walls, with a smaller offset pipe opening visible at the upper left.

  • HVACWork status not resolved

    Photograph shows a white PVC condensate drain fitting protruding from the base of an exterior HVAC unit cabinet, with a dark wet stain and debris visible on the rooftop or concrete surface directly below the drain outlet.

  • HVACWork status not resolved

    Photograph shows a rooftop packaged HVAC condenser unit mounted on a roof curb, with conduit and refrigerant lines running across the flat roof surface to adjacent equipment.

  • HVACWork status not resolved

    Photograph shows white soffit/fascia panels beneath a roof overhang with visible dark vertical streaking, staining, and debris speckling across the panel surfaces; a horizontal pipe or conduit is mounted along the top edge of the soffit.

  • HVACWork status not resolved

    additional rooftop units are visible in the background

  • HVACWork status not resolved

    Photograph shows a commercial rooftop package unit with an access panel open exposing internal components (burner/heat exchanger assembly), with tools, pipe sections, hoses, and supplies laid out on the roof surface indicating active service work in progress.

  • HVACWork status not resolved

    Photograph shows close-up view of parallel metal pipes with visible rust-colored staining, mineral deposits, and discoloration concentrated along the seams and joints between pipe surfaces.

  • HVACWork status not resolved

    Photograph shows the top surface of an HVAC air handler with a large dark moisture stain and scattered smaller spots; a dark rectangular pad or sponge is resting on the stained area, and a return air grille is visible on the unit top.

  • HVACWork status not resolved

    Photograph shows a large commercial rooftop packaged HVAC unit (RTU) mounted on a flat gravel-surfaced roof, with condenser coil mesh screens visible on the left side, access panels on the right, and additional rooftop units visible in the background; pipe stubs and conduit are present on the roof surface adjacent to the unit.

  • HVACWork status not resolved

    Photograph shows the interior of an outdoor condenser unit with multiple metal coil tubes/pipes exhibiting visible rust and surface corrosion, along with accumulated dust and debris along the base channel.

  • HVACWork status not resolved

    Photograph shows rectangular metal ductwork at a ceiling junction with visible dark streaking and staining across duct surfaces; white sheeting is present below.

  • HVACWork status not resolved

    Photograph shows multiple parallel metal heat exchanger tubes with visible surface rust and corrosion streaking along the seams and outer surfaces.

  • HVACWork status not resolved

    Photograph shows the interior of an open rooftop packaged HVAC unit with visible inducer/draft motor, wiring harness, gas valve, and burner assembly area; significant dust and debris accumulation is present on the base pan and components, and wet spots are visible on the surrounding roof surface.

  • HVACWork status not resolved

    Photograph shows a window frame assembly with a visible vertical crack and gap at a frame joint, accompanied by rust/corrosion staining and deteriorated material at the base of the frame.

  • HVACWork status not resolved

    Photograph shows multiple large cylindrical metal tubes, consistent with heat exchanger or flue components, exhibiting visible rust and corrosion streaking along their surfaces; reflective foil insulation is visible in the background.

  • HVACWork status not resolved
  • UnclassifiedWork status not resolved

    Photograph shows a white-painted horizontal pipe or tube with visible rust spots, corrosion pitting, and dark staining at multiple points, mounted within a white metal structural frame against a textured masonry wall; a gap is visible between framing members above.

  • UnclassifiedWork status not resolved

    Photograph shows a galvanized steel slotted bracket mounted at the base of a white-painted door frame, adjacent to a metal track channel at floor level, with loose fasteners visible on the concrete floor nearby.

  • HVACWork status not resolved

    Photograph shows a large round metal duct elbow with visible rust and corrosion, secured with a wire band, adjacent to a blower wheel; the ductwork shows significant aging and deterioration.

  • HVACWork status not resolved

    HVAC tech requested to inspect a unit with an oiled substance leaking from the ceiling between loft 8 and 9 at the Des Peres Salon location; work order is pending acceptance.

  • UnclassifiedWork status not resolved

    Photograph shows a pile of galvanized metal tubes and channel sections with visible surface rust streaks and dirt accumulation along their lengths.

Record 4Public property record

HVAC Parts Invoice — Trane OEM evap coil pans and drain line

  • HVAC

On August 12, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 12139 Manchester Road, St. Louis, MO 63131.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$900

    Supplied two Trane OEM evaporator coil pans and drain line.

  • HVACWork status not resolved

    Photograph shows a commercial rooftop HVAC package unit with gray sheet-metal panels and access doors, a mesh condenser coil section, and a white PVC condensate drain line with a P-trap assembly at the unit base; dark staining is visible on the flat roof surface around the drain outlet.

  • HVACWork status not resolved

    Photograph shows interior of an HVAC coil cabinet with multiple rows of copper refrigerant tubing and U-bend return bends exhibiting significant reddish-brown corrosion and oxidation; moisture and debris are visible in the drain pan area below, and rust staining is present on the sheet metal cabinet walls.

  • HVACWork status not resolved

    Photograph shows a black threaded roof drain fitting surrounded by heavily cracked, peeling, and lifting aluminum/silver sealant compound, with visible rust or corrosion along a nearby seam on the flat roof surface.

  • HVACWork status not resolved

    Photograph shows heavily corroded and oxidized copper refrigerant coil tubing and U-bend returns inside an HVAC unit, with rust debris visible at the base of the unit.

  • HVACWork status not resolved

    Photograph shows a flat/low-slope built-up or modified bitumen roof with granulated membrane panels, dark seam tape at panel joints, an open gap in the roof membrane near the center, removed or displaced metal flashing pieces and a cardboard tube lying on the surface, pipe/conduit penetrations on the left side, and apparent moisture or wet residue near the lower left.

Record 5Public property record

HVAC Warranty Service — Warranty diagnostic visit, no charge

  • HVAC

On August 20, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 12139 Manchester Road, St. Louis, MO 63131.

Record date

Available findings

  • HVACCompleted work

    Warranty service visit: technicians came out to diagnose the unit and determine the cause of the issue, following a previous diagnosis where something may have been missed.

  • HVACWork status not resolved

    Photograph shows the lower exterior section of a large HVAC unit with an open access compartment, torn or damaged foil-faced insulation along the base rail, and a white PVC condensate or drain line visible at the lower right corner.

  • HVACWork status not resolved

    Photograph shows a label on HVAC equipment identifying Rooftop Unit 4 (RTU-4) with unit number 173912335L; label is partially torn at the top edge.

  • HVACWork status not resolved

    Photograph shows an HVAC evaporator coil assembly with copper U-bend refrigerant tubing exhibiting reddish oxidation/corrosion, black electrical wiring, and visible moisture (water droplets) on the drain pan surface inside the air handler cabinet.

  • HVACWork status not resolved

    Photograph shows a white PVC pipe (marked 3/4 SCH40) penetrating an exterior wall through a patched/sealed opening, connected with a compression union fitting; foil-faced insulation duct is visible at the upper left.

  • HVACWork status not resolved

    Photograph shows the interior of an open HVAC air handler cabinet with a heavily soiled, rust-stained blower compartment floor and a new air filter (MERV-rated) being inserted into the filter slot.

  • HVACWork status not resolved

    Photograph shows a white PVC pipe penetrating through the base of a metal equipment enclosure panel, with deteriorated, peeling sealant/caulk material around the pipe at the penetration point; purple primer/cement is visible on the pipe near the fitting.

  • HVACWork status not resolved

    Photograph shows a rooftop packaged HVAC unit with visible rust and corrosion on the base pan and internal surfaces, bundled electrical wiring entering the unit's electrical compartment, yellow foam insulation at the unit edge, and dark staining on the roof surface beneath the unit; a partial label reads 'YHC072F3RLA0LH0C10000D / BAY LINE'.

  • HVACWork status not resolved

    Photograph shows a large metal HVAC unit with a rectangular duct opening; metallic foil tape has been applied along the lower edge of the opening over a foam/insulation strip, and rust/corrosion staining is visible along the right-side duct frame seam.

  • HVACWork status not resolved

    Photograph shows interior of an HVAC evaporator coil cabinet with heavily oxidized/corroded copper refrigerant tubing, a drain pan with visible moisture staining and debris, greenish corrosion on the sheet metal base, and deteriorated insulation material.

  • UnclassifiedWork status not resolved

    Photograph shows a brown stain or dried spill on light gray vinyl plank flooring in what appears to be a commercial salon setting, with salon chairs visible in the background.

  • UnclassifiedWork status not resolved

    Photograph shows the interior of an open storage compartment (likely a truck bed toolbox) with a heavily scratched and soiled floor surface, visible rust/corrosion along the metal lower edge, and a small wired electrical component (latch actuator or solenoid) mounted in the upper corner.