HVAC Installation — 3-ton 17 SEER2 A/C + evaporator coil
- HVAC
On June 11, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 12149 Theiss Meadows Drive, St. Louis, MO 63128.
- Record date
Documented details
- Outcome: Paid in full
Available findings
- HVACCompleted work$8,086
Installed a 3-ton American Standard 17 SEER2 two-stage air conditioner and matching evaporator coil, with labor, condenser pad, 30-amp disconnect and install materials.
- HVACWork status not resolved
Photograph shows a gray multi-sided outdoor air conditioning condenser unit mounted on a concrete pad against a brick exterior wall, with insulated refrigerant lines running into the building and a disconnect box mounted on the wall nearby.
- HVACWork status not resolved
Photograph shows an outdoor air conditioning condenser unit mounted on a concrete pad along the side of a brick residential home, with refrigerant lines running along the exterior wall and overgrown vegetation around the unit base.
- HVACWork status not resolved
Photograph shows a high-efficiency gas furnace installed in a basement, with multiple white PVC pipes for intake, exhaust flue, and condensate drainage, along with foil-taped duct connections and a visible control/electrical box on the unit's side.
- HVACWork status not resolved
Fieldpiece app refrigerant side measurements show R-454B refrigerant with suction pressure 130.8 psig, liquid pressure 348.1 psig, actual superheat 18.6°F, and actual subcooling 11.9°F.
- HVACWork status not resolved
Model 5A7A7036A1000AA, Serial 26084UC3HF, manufactured 2/2026, R454B-A2L refrigerant, 208–230V, 29.0A MCA, 40A max fuse/breaker
- HVACWork status not resolved
Fieldpiece refrigerant side measurements show R-454B system with suction pressure 131.0 psig, liquid pressure 346.8 psig, actual superheat 18.2°F, and actual subcooling 11.6°F.
- HVACWork status not resolved
5PXCB003AS3HAAA, Serial No. 26215HL85G) indicating R-454B refrigerant (A2L flammable classification) and a maximum allowable pressure of 650 PSI, assembled in USA