HVAC Diagnostic Service — Residential HVAC diagnostic service
- HVAC
On September 11, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 1221 Gruner Place, St. Louis, MO 63133.
- Record date
Documented details
- Outcome: Paid in full
Available findings
- HVACCompleted work$125
Residential diagnostic service performed at 1221 Gruner Place.
- HVACWork status not resolved
Photograph shows a large gray HVAC air handler unit mounted on a white painted platform in a basement utility area, with PVC condensate drain piping and black flexible piping exiting the unit base; black sheeting covers most of the surrounding floor.
- HVACWork status not resolved
Photograph shows an equipment data plate on an HVAC coil unit (model AE36BX21G, serial W2E1012062), rated 208/230V, 1 PH, 60 HZ, with 1/2 HP motor and refrigerant R22/R407C/R410A compatibility.
- HVACWork status not resolved
Photograph shows the data plate of an outdoor HVAC condenser unit, model YHE36B22SB, serial W2E1007206, using R-410A refrigerant with a factory charge of 9 lbs 1 oz; the installer's Total Charge fields are blank.
- HVACWork status not resolved
Photograph shows a Yellow Jacket two-gauge Test and Charging Manifold (blue low-side and red high-side gauges) with brass body, compatible with refrigerants R-454B and R-32, date code 2024.
- HVACWork status not resolved
Photograph shows dark brown/black spotty deposits consistent with mold or mildew growth visible along the edge of a window or door frame and within the gap between the frame and the surrounding wall surface, with debris accumulation also present.
- UnclassifiedWork status not resolved
Google search result showing Zillow and AI Overview data for 1221 Gruner Pl, Saint Louis, MO 63133 — a 938 sq ft, 2-bed, 1-bath single-family bungalow built in 1926 on a 4,478 sq ft lot; property is currently not for sale.
- UnclassifiedWork status not resolved
Photograph shows a blurry, low-light view of a wall surface with scattered small dark spots adjacent to a dark, glossy vertical element, alongside what appears to be a wall corner or door frame edge.
- HVACWork status not resolved
Photograph shows a visible gap or separation between interior wall panels at their junction, in what appears to be a basement or lower-level utility space with exposed ceiling framing above; a ladder and materials are visible in the background through the opening.
- HVACEstimate or proposed work$125
- HVACWork status not resolved
Photograph shows the interior of an HVAC evaporator coil compartment with heavily soiled, darkened fin coil surfaces on both sides of the cavity, and what appears to be a plastic bag or loose debris/sheeting lodged inside the coil; a wire or drain line is visible at the bottom of the compartment.