  • HVAC
    HVAC · AC condenser and coil replaced with new R410A system · Jul 2022
  • HVAC
    HVAC · New furnace proposed for installation · Jul 2024
  • HVAC
    HVAC · Furnace board and pressure switch replaced after water damage · Oct 2022
  • HVAC
    HVAC · Gas valve replaced and gas system pressure tested · Dec 2022
Ask this homePowered by Fresh House property intelligence®
THE HOME

Hi, I'm 1229 Oxford Hill Court. I only speak from this property's source-backed records — 10 documents from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.

ASK ME ABOUT

RECORD SUMMARY

10 documented events
Contributed by: 1 contributor
First documented event: Jul 2022
Latest documented event: Jul 2024
First added to Fresh House: Nov 2026
Fresh House

Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.

DOCUMENTED HISTORY

This page contains 10 documented records for 1229 Oxford Hill Court, St. Louis, MO 63146, dated from July 2022 through July 2024. The amount summary includes $11,891.40 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.

HVAC

HVAC Service Call — Compressor smoking; unit shut down

Document dated Jul 7, 2022Uploaded Nov 10, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 1229 Oxford Hill Court, St. Louis, MO 63146.
Scope
  • HVAC
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $63
  • HVACService call for no AC: found indoor breaker tripped on one leg, reset it, found compressor smoking, shut unit down and recommended AC/coil replacement; furnace functioning as intended.
    $63

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Ductwork — 2-ton 13 SEER condenser and coil install

Document dated Jul 18, 2022Uploaded Nov 10, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 1229 Oxford Hill Court, St. Louis, MO 63146.
Scope
  • HVAC
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $3,891
  • HVACInstalled a Sure Comfort by Rheem 2 ton 13 SEER R410A condensing unit with TXV coil, including fused disconnect, electrical whip, pad, sheet metal adaptation to ductwork, and chemical flush and pressure test of the line set.
    $3,891
warranty5 year / 10 year / 20 yearFrom invoiceView details
Documented warrantyfrom invoice · Jul 18, 2022HVAC · 4 terms

What this warranty covers

5 year
  • parts
    · source

    “All equipment installed comes with a 5 year parts warranty”

10 year
  • compressor
    · source

    “10 year compressor warranty”

  • parts/compressor
    · source

    “Once equipment is registered this will become 10 year parts/compressor warranty”

20 year
  • heat exchanger
    · source

    “20 year heat exchanger warranty”

Coverage based on an invoice. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Work — Corrected miswired low voltage wiring on furnace

Document dated Jul 26, 2022Uploaded Nov 10, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 1229 Oxford Hill Court, St. Louis, MO 63146.
Scope
  • HVAC
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $75
  • HVACUpon arrival for a no AC call, low voltage wires on the indoor furnace were found wired wrong; wiring was corrected and the system worked as intended.
    $75

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Work — Low voltage wiring corrected on both units

Document dated Aug 2, 2022Uploaded Nov 10, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 1229 Oxford Hill Court, St. Louis, MO 63146.
Scope
  • HVAC
Contributor
worked on or inspected it

Built from Housecall Pro data

  • HVACFound low voltage wiring wired wrong to each unit; traced each circuit, rewired everything to proper functions, and tested both systems, which worked as intended.

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Service Call — System working as intended

Document dated Sep 29, 2022Uploaded Nov 10, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 1229 Oxford Hill Court, St. Louis, MO 63146.
Scope
  • HVAC
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $75
  • HVACNo AC call: on arrival the system was found working as intended; wire connections, thermostat, system charge and controls were checked.
    $75

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Work — New board and pressure switch; water damage

Document dated Oct 25, 2022Uploaded Nov 10, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 1229 Oxford Hill Court, St. Louis, MO 63146.
Scope
  • HVAC
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $550
  • HVACNo heat call: needed new board and pressure switch due to water damage; universal board supplied.
    $550

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Service Call — Ignition proving failure; burners cleaned

Document dated Nov 17, 2022Uploaded Nov 10, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 1229 Oxford Hill Court, St. Louis, MO 63146.
Scope
  • HVAC
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $50
  • HVACFound unit off on safety due to ignition proving system failure; cleaned burners, safeties and gas pistons, and all systems were working as expected at completion.
    $50

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Gas Valve Replacement — Gas valve replaced, gas system pressure

Document dated Dec 23, 2022Uploaded Nov 10, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 1229 Oxford Hill Court, St. Louis, MO 63146.
Scope
  • HVAC
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $75
  • HVACReplaced customer supplied gas valve and pressure tested the gas system.
    $75

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Furnace Installation — 80% gas furnace, 50,000/75,000 BTU

Document dated Jul 16, 2024Uploaded Nov 10, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 1229 Oxford Hill Court, St. Louis, MO 63146.
Scope
  • HVAC
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $3,213
  • HVACWork performed: OH 29-3 / PO - 2185301; 80% Furnace Only 50,000/75,000 BTU (We propose to install the following equipment in listed unit); Payment Terms Net 30/45; Terms and Conditions.
    $3,213

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC AC/Coil Replacement — 2-ton R410A condenser and coil replaced

Document dated Jul 18, 2024Uploaded Nov 10, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
ASSURED HEATING AND COOLINGdocumented HVAC at 1229 Oxford Hill Court, St. Louis, MO 63146.
Scope
  • HVAC
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $3,900
  • HVACWork performed: Coil/Condenser 2 Ton R410A System (We propose to install the following equipment in above listed unit); Warranty (Equipment Warranty); Payment Terms Net 30/45; Terms and Conditions.
    $3,900
warrantyfive-year / ten-year / twenty-yearFrom invoiceView details
Documented warrantyfrom invoice · Jul 18, 2024HVAC · 5 terms

What this warranty covers

five-year
  • parts
    · source

    “manufacturer five-year parts warranty”

  • labor
    · source

    “Contractor offers a five-year labor warranty on all new equipment installed by contractor.”

ten-year
  • compressor
    · source

    “ten-year compressor warranty”

  • parts
    · source

    “Once the equipment has been properly registered, the five-year manufacturer parts warranty becomes a ten-year parts warranty.”

twenty-year
  • heat exchanger
    · source

    “a twenty-year heat exchanger warranty”

Coverage based on an invoice. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.

Only original contributor can modify this entry

Create an account to manage your contributions over time

Only the original contributor can modify this entry · Create an account to manage your contributions over time.

Add inspections, repairs, appraisals,
or anything that shaped this home.

PROPERTY COVERAGE

HVAC
✓ documented
Home Inspection
undocumented
Roof
undocumented
Plumbing
undocumented
Sewer
undocumented
Foundation
undocumented
Mold
undocumented
Electrical
undocumented
Pest
undocumented
Radon
undocumented
Appraisals
undocumented
Windows
undocumented

Nearby homes with documented history