HVAC Gas Line Inspection — Dry-rotted gas seals, rodent damage
- HVAC
On January 14, 2021, ASSURED HEATING AND COOLING documented HVAC at 12418 Big Bend Road, Kirkwood, MO 63122.
- Record date
Documented details
- Outcome: Paid in full
Available findings
- HVACCompleted work$89
Gas line and flue pipe inspection found 1" gas pipe parts needing removal and resealing due to dry rotted joint seals, rodent damage to second floor unit high voltage wiring, a lower unit exhaust not up to code, and minor AC disconnect wire repairs needed.
- HVACWork status not resolved
Photograph shows an outdoor air conditioning condenser unit adjacent to a brick foundation wall; the wall-mounted electrical disconnect box exhibits significant rust and corrosion on its lid and housing, a flexible conduit runs from the disconnect to the unit, and a white PVC pipe elbow protrudes from the foundation wall nearby; dead leaves are accumulated around the unit.
- HVACWork status not resolved
Photograph shows electrical cable with visible conductors passing through a rough, unprotected hole in wood sheathing/framing at a wall-floor junction, with no protective bushing or grommet, and cobwebs indicating the area has been undisturbed.
- HVACWork status not resolved
Photograph shows an electrical cable routed through a notch in a wood framing member with the outer black jacket visibly damaged and the inner red-insulated conductor exposed, along with cobwebs and debris accumulation.