Hi, I'm 1243 Darding Drive. I only speak from this property's source-backed records — 1 document from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.
1243 Darding Drive
Across 1 record on this home
Completed work
Invoices and paid receipts
Estimated · not confirmed
Quotes, estimates, and other amounts not confirmed as performed
Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 1 documented records
Fresh House Property Summary
Highlights selected from 1 documented record for this property.
- HVAC · AC dual capacitor replaced during an overtime diagnostic visit · Aug 2026
- HVAC · Resident reported AC not cooling; technician found system blowing cold air · 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 1 documented record for 1243 Darding Drive, St. Louis, MO 63125. The amount summary includes $535 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Capacitor Repair — Dual capacitor replaced
- HVAC
Built from Housecall Pro data
- $535HVACPerformed an overtime diagnostic and replaced the dual capacitor.
- HVACResident reports air conditioner is not cooling; probable diagnosis is AC blowing cold air but home is too hot, with thermostat set correctly and vents open and clear.
- HVACPhotograph shows a metal HVAC unit (likely a furnace) with a manufacturer label reading Model S8X1B060MPS, Serial No. 203965H5JG, Line F2, dated 09/26/2020.
- HVACFieldpiece app refrigerant side measurements show R-410A system with suction pressure 146.7 psig, liquid pressure 294.7 psig, actual superheat 17.0°F, and actual subcooling 13.7°F.
- HVACFieldpiece app refrigerant diagnostic shows R-410A system with suction pressure 147.9 psig, discharge pressure 358.2 psig, actual superheat 15.2°F, and actual subcooling 10.0°F; Air Side Diagnostic dry bulb values not entered.
- HVACPhotograph shows a gas furnace unit installed in an unfinished basement mechanical room, connected to sheet metal supply ductwork above, a round metal flue/exhaust pipe, flexible conduit, gas piping, with a red fire extinguisher mounted nearby and a stack of replacement air filters on a wooden shelf.
- HVAC4PXCBU30BS3HAAA, serial no. 21093WS35G, refrigerant type R-410A only, and design PSI 480, assembled in USA
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,