- HVAC · AC system found frozen over, thawed, and refrigerant added · Jun 2026
- HVAC · AC dual capacitor replaced on a no-cooling service call · Jul 2026
- HVAC · AC checked for no cooling; unit working, portable AC recommended for bedrooms · May 2026
- HVAC · Seasonal heating maintenance done on vacant property; new filter installed · Nov 2025
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 4 documented records for 12464 Glengate Drive, Maryland Heights, MO 63043, dated from November 2025 through July 2026. The amount summary includes $1,006.48 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Service Call — No AC call; 45 + 5 Mfd capacitor supplied
- HVAC
Built from Housecall Pro data
- $369HVACService call for no AC with labor performed and a 45 + 5 Mfd dual capacitor supplied.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Seasonal Maintenance — Seasonal maintenance; system working
- HVAC
Built from Housecall Pro data
- $89HVACSeasonal maintenance on a vacant property: system was working as expected, heat tested, all safeties cleaned, and new 16x25x1 filter put in place.
- HVACPhotograph shows interior of an HVAC air handler unit with an HDX brand 16x25x1 air filter installed, visible circuit board with multi-color wiring, and significant dust and debris accumulation on unit surfaces.
- HVACPhotograph shows a gas furnace with access panels removed, exposing the blower motor, control board, wiring harness, capacitors, and internal components; a metal exhaust flue exits the top of the unit.
- HVACPhotograph shows a gas furnace with a galvanized metal flue/vent pipe rising from the unit, connected via an elbow to overhead ductwork, with foil tape applied at the pipe's passage through a sheet metal panel; electrical wiring and copper tubing are also visible alongside the unit.
- HVACPhotograph shows the top of a gas water heater with copper hot and cold water supply lines, brass fittings and shutoff valve, and galvanized sheet metal flue/vent pipes connecting to an overhead vent stack; mineral deposits and corrosion are visible at the base of the vent collar where it meets the tank.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — AC working as should; portable AC advised
- HVAC
Built from Housecall Pro data
- $154HVACService call to check the AC filter, blower and outdoor unit; equipment found working as it should, and portable air conditioning was recommended for the bedrooms.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — Frozen AC system, R410a added
- HVAC
Built from Housecall Pro data
- $394HVACService call for no AC: system found frozen over and turned off to thaw, labor performed, and R410a refrigerant added by the pound; return visit planned.