On September 23, 2026, Greensmith Home Inspection llc documented Electrical, Foundation, HVAC, and 5 other topics at 126 Cherry Hill Drive, Fenton, MO 63026.
- Record date
Available findings
- Home InspectionWork status not resolved
Whole-home inspection of single-family property found no structural issues; deficiencies noted across electrical, HVAC, pest, and site systems, including missing smoke detectors, a missing panel breaker, GFCI outlet deficiencies, termite/carpenter bee damage, and a 1992 AC condenser approaching end of life.
- ElectricalWork status not resolved
Square D 125-amp panel (aged, likely needs replacing in next few years) has a missing breaker; smoke detectors are not present throughout the home; rear patio outlet needs GFCI replacement; kitchen sink right-side outlet needs GFCI replacement; 2-prong ungrounded outlets present.
- HVACWork status not resolved
Sure gas furnace (100,000 BTU, manufactured 2025) is functional; York 2.5-ton AC condenser (manufactured 1992) is performing but needs cleaning and servicing and is approaching end of expected life.
- PlumbingWork status not resolved
AO Smith 50-gallon electric water heater (manufactured 2025) is functional with T&P relief valve present; copper supply pipes and PVC waste pipes are in satisfactory condition.
- RoofWork status not resolved
Architectural shingle roof estimated 5-7 years old is installed correctly and in satisfactory condition; gable design with ridge vents, metal flashings, and metal gutters all satisfactory.
- FoundationWork status not resolved
Slab-on-grade poured concrete foundation is in satisfactory condition with no structural issues observed; wood frame walls and wood truss roof framing are satisfactory.
- PestWork status not resolved
Minor termite damage is present on trim around the garage entry door and carpenter bee damage is present on the fascia board on the east side of the home no mud tubes or nests were observed
- WindowsWork status not resolved
Vinyl and wood exterior windows are in satisfactory condition; kitchen window has been painted shut and needs to be opened.
- PestWork status not resolved
Visible evidence of wood destroying insects found: older termite damage on garage door and trim, and carpenter bee damage on house fascia; treatment recommendation is to spray affected areas with a borate-based solution.