Record 1Public property record

HVAC Diagnostic Service — Diagnostic trip fee and 2.5 hours labor

  • HVAC

On January 26, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 1260 Gahan Drive, Florissant, MO 63031.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$414

    Work performed: Diagnostic Trip Fee; Labor, quantity 2.5.

Record 2Public property record

HVAC Work — Single speed draft motor supplied

  • HVAC

On January 26, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 1260 Gahan Drive, Florissant, MO 63031.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$699

    Trip fee charged and a single speed draft motor supplied.

  • HVACWork status not resolved

    Photograph shows the interior of a furnace with a draft inducer blower motor assembly; the centrifugal blower wheel exhibits visible dust and debris accumulation on the blades, with orange and yellow wiring harnesses and a white electrical connector visible.

  • HVACWork status not resolved

    Photograph shows the interior of a gas furnace with the access panel removed, revealing the inducer/draft blower motor, yellow flexible gas connector, gas valve, burner assembly, and wiring; significant dust, debris, and general deterioration are visible throughout the unit and surrounding basement floor.

  • HVACWork status not resolved

    Photograph shows the interior of a gas furnace with access panel removed, revealing multiple burners actively firing with blue and orange flame, a draft inducer motor assembly at top, a gas valve connected via yellow corrugated flexible gas line, and associated wiring harnesses; a water heater tank is partially visible to the right.

  • HVACWork status not resolved

    Photograph shows the interior of a gas furnace with the access panel removed, revealing a draft inducer/blower motor assembly, yellow corrugated flexible gas supply line, multi-colored wiring harness, and a gas valve assembly at the lower right.

  • HVACWork status not resolved

    Photograph shows the interior of a gas furnace with the access panel removed, revealing the draft inducer blower motor (with visible dust/debris accumulation on the motor hub), yellow corrugated flexible gas supply line, a gas valve labeled 'GAS FLOW', multiple wiring harnesses, and a pressure switch assembly.

  • HVACWork status not resolved

    Photograph shows a gas furnace in a basement with its front access panel removed, exposing the blower motor, wiring harness, and burner assembly with an active blue flame; the unit appears aged with significant dust accumulation and worn components. A large cylindrical water heater is visible to the right, and sheet metal supply ductwork runs overhead.

  • HVACWork status not resolved

    Photograph shows the interior of a gas furnace with multiple burner tubes exhibiting heavy rust and corrosion on the burner assembly, manifold bracket, and surrounding metal components; a motor assembly is visible at the top and a multi-wire harness runs along the lower foreground.

  • HVACWork status not resolved

    Photograph shows an HVAC centrifugal blower motor assembly (squirrel cage blower with electric motor attached) packed in a cardboard shipping box with brown paper padding.

  • HVACWork status not resolved

    Photograph shows a basement mechanical area with an aged gas furnace (access panel open exposing internal components), a large sheet-metal air handler/coil cabinet, a whole-house humidifier connected to the supply duct, flexible yellow gas lines, sheet-metal supply and return ductwork, flue exhaust piping, and associated electrical wiring; an orange service sticker is visible on the furnace cabinet but is not legible.

  • HVACWork status not resolved

    Photograph shows a UEI G2 Phoenix clamp meter (PRO+ DL389 TRMS) with test leads connected, displaying readings of 00.16 and 120.8 on its LCD screen, being used in a utility room with visible wiring, HVAC equipment, and a water heater in the background.

Record 3Public property record

HVAC Igniter Replacement — Hot surface igniter replaced

  • HVAC

On February 2, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 1260 Gahan Drive, Florissant, MO 63031.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$432

    Replaced the hot surface igniter on the furnace and a trip fee was charged.

  • HVACWork status not resolved

    Photograph shows interior of an open gas furnace with visible inducer motor, burner/heat exchanger assembly with surface rust and corrosion, gas manifold, blower motor, and control board with an illuminated amber/orange LED indicator light; a 16x25x1 air filter is installed in the filter slot.

  • HVACWork status not resolved

    Photograph shows the interior of a gas furnace with the access panel removed, burners actively firing (visible orange glow), gas manifold and valve assembly, inducer motor, wiring harness, and a 16x25x1 air filter visible on the left; a technician's hand is visible at lower right.

  • HVACWork status not resolved

    Photograph shows the interior of a gas furnace with the access panel removed, revealing the inducer motor, gas valve, flexible yellow gas supply line, multi-port burner assembly with active blue and orange flames, and associated wiring; a cylindrical tank (likely a water heater) is visible to the right.

  • HVACWork status not resolved

    Photograph shows the interior of a gas furnace with the access panel removed, multiple burners actively firing with blue and orange flames visible, a gas valve, yellow flexible gas supply line, wiring harness, and blower motor assembly; a technician's hand is visible at the lower right.

  • HVACWork status not resolved
  • UnclassifiedWork status not resolved

    description section is collapsed and trade/system cannot be determined from visible content

View 1260 Gahan Drive, Florissant, MO 63031 on Fresh House