Complete public upload archive

Property records for 12654 Treeyard Lane, St. Louis, MO 63138

All 9 public upload records returned by the Fresh House property feed are available across 1 server-rendered page. This page shows records 1 to 9.

Record details are source-backed where available. Permit status and descriptions repeat the publishing agency's data; they do not independently establish that work was completed.

Return to the property overview
Record 1Public property record

HVAC Diagnostic Service Call — Water heater burner flame abnormal

  • Foundation
  • HVAC
  • Roof
  • Sewer

Arch Air Services documented Foundation, HVAC, Roof, and Sewer at 12654 Treeyard Lane, St. Louis, MO 63138.

Available findings

  • HVACCompleted work$159

    Restored gas service, tested furnace gas pressure (14.75" wc standby, 5.46" wc running), confirmed heating supply temp 120°F and temp rise 53°, emptied flue tee cleanout buildup, replaced pleated filter; water heater was lit but burner flame was unsteady (going across burner plate) and was left off pending installer follow-up.

  • FoundationWork status not resolved

    Photograph shows a small white fluted circular container filled with granular material resting on a concrete floor surface that displays significant discoloration and weathering.

  • HVACWork status not resolved

    Photograph shows a UEi EM152 differential pressure manometer displaying a reading of 54.6, held in front of HVAC equipment internals with visible wiring and components.

  • RoofWork status not resolved

    Photograph shows a reddish-brown cylindrical chimney or vent stack with a multi-louvered cap mounted on a dark asphalt shingle roof, with no visible damage to the surrounding shingles.

  • SewerWork status not resolved

    Photograph shows the interior of a circular pipe viewed from a camera, with visible buildup or debris along the pipe walls and a small light source visible at the far end.

  • RoofWork status not resolved

    Photograph shows a brick chimney viewed from above with a flat gray metal chimney cap installed over the flue opening; brick masonry is visible at the chimney crown and surrounding rooftop area.

  • HVACWork status not resolved

    Photograph shows insulated flexible ducts connected to a sheet metal tee or wye fitting mounted near a concrete/block foundation wall in what appears to be a basement; a yellow warning label is visible on one duct.

  • HVACWork status not resolved

    Photograph shows the interior of an open furnace with a handheld digital measurement device (displaying a reading of 1466) connected via a flexible probe tube, suggesting an active diagnostic or combustion/pressure test being performed on the unit.

Record 2Public property record

Pest Mole Control Invoice — Mole control initial service

  • Pest

This record, dated September 14, 2026, documents Pest at 12654 Treeyard Lane, St. Louis, MO 63138.

Record date

Available findings

  • PestCompleted work$169

    General pest control initial service performed at 12654 Treeyard Ln; technician treated all accessible eaves, doors, windows, foundation, perimeter, garage, and interior areas using Demand CS, Talstar P, Termidor SC, and InTice Gelanimo Ant Bait targeting ants, beetles, centipedes, crickets, nonpoisonous spiders, and pillbugs; investor discount applied.

  • PestCompleted work$550

    Technician inspected and treated all visible mole activity focusing on newer runs, applying Talpirid (Bromethalin 0.02%) bait in the yard; all baited areas marked — Mole Control Quarterly Plan Initial Service.

Record 3Public property record

Plumbing Repair Invoice — Kitchen disposal and drain pipe leak

  • Plumbing

On May 19, 2026, Drain Clean USA, LLC documented Plumbing at 12654 Treeyard Lane, St. Louis, MO 63138.

Record date

Available findings

  • PlumbingCompleted work$250

    Removed kitchen pipe and garbage disposal, then reinstalled disposal and drain pipe with no leaks at this time.

Record 4Public property record

Electrical Panel Replacement — Eaton 200-amp panel replaced split

  • Electrical

On October 7, 2025, Electrical & Data Service Co. documented Electrical at 12654 Treeyard Lane, St. Louis, MO 63138.

Record date

Available findings

  • ElectricalCompleted work$2,810

    Furnished and installed a new Eaton 200amp main breaker 30/60 circuit panel to replace the existing 200amp split bus panel, new breakers, and a new #2 USE aluminum waterpipe ground; St. Louis County electrical permit and inspection availability included.

Record 5Public property record

Electrical Panel Replacement — Eaton 200-amp panel replaced split

  • Electrical

This record, dated October 7, 2025, documents Electrical at 12654 Treeyard Lane, St. Louis, MO 63138.

Record date

Available findings

  • ElectricalCompleted work$2,810

    Furnished and installed a new Eaton 200amp main breaker 30/60 circuit panel to replace the existing 200amp split bus panel, new breakers (various amperage), a new #2 USE aluminum waterpipe ground, and St. Louis County electrical permit; work completed 10/6/25.

Record 6Public property record

HVAC System Installation — RunTru 80K BTU furnace + 3-ton 13 SEER A/C

  • HVAC

On October 6, 2025, Arch Air Services documented HVAC at 12654 Treeyard Lane, St. Louis, MO 63138.

Record date

Available findings

  • HVAC$7,475

    Installed complete HVAC system including a new Run Tru single-stage 80,000 BTU 80% furnace and Run Tru 3-ton 13 SEER air conditioner with matching cased insulated evaporator coil, new Emerson Digital thermostat, mechanical permit, and all associated labor and materials including new electrical disconnect box, wire whip, gas line reconfiguration, flue pipe, condensate drain system, and removal of existing equipment.

Record 7Public property record

HVAC Repair Service — Bad control board replaced under warranty

  • HVAC

On December 3, 2025, Arch Air Services documented HVAC at 12654 Treeyard Lane, St. Louis, MO 63138.

Record date

Available findings

  • HVAC$0

    Diagnosed blower motor not actuating due to bad control board; warranty board ordered and installed, system tested and confirmed heating properly.

Record 8Public property record

HVAC Blower Repair Invoice — Trane blower wiring harness replaced

  • HVAC

On December 29, 2025, Arch Air Services documented HVAC at 12654 Treeyard Lane, St. Louis, MO 63138.

Record date

Available findings

  • HVAC$0

    Removed old blower wiring harness and installed new warranty harness on a Trane system; tested system in heat mode confirming correct operation after running diagnostics with Trane tech support through multiple cycles.

Record 9Public property record

Inspection

  • HVAC
  • Sewer

This record, dated August 1, 2025, documents HVAC and Sewer at 12654 Treeyard Lane, St. Louis, MO 63138.

Record date

Record description

Completed full renovation on this home. All new roof, new HVAC, and new electrical panel along with new interior vanities and new appliances

View 12654 Treeyard Lane, St. Louis, MO 63138 on Fresh House