HVAC Maintenance — Condenser fan motor and capacitor
- HVAC
On June 7, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 1266 Bal Harbor Drive, Arnold, MO 63010.
- Record date
Documented details
- Outcome: Paid in full
Available findings
- HVACCompleted work$700
Performed a residential diagnostic service and provided a condenser fan motor and capacitor.
- HVACWork status not resolved
Photograph shows an outdoor HVAC condenser unit with heavy rust on the fan guard, fan motor housing, and top panel; a Testo refrigerant manifold gauge set is connected to the unit's service ports, and test leads/wiring are clipped to the motor.
- HVACWork status not resolved
Photograph shows a data plate on an HVAC fan coil unit, Model FA4ANF024, Serial No. 2296A14273, rated 208/230V, 1/6 HP motor, Refrigerant 22 at 300 PSIG design, with Heat Pack listed as N/A.
- HVACWork status not resolved
Photograph shows an outdoor air conditioning condenser unit with data plate reading Model 38CKB024320, Serial 2496E05920, factory charged with R-22 refrigerant (4.50 lbs), 208-230V/1PH/60Hz power supply, 11.6 RLA compressor, and minimum circuit amps of 15.4.
- HVACWork status not resolved
Photograph shows a Testo 557 digital manifold gauge connected to an outdoor condenser unit, displaying refrigerant type R-22, ambient/line temperature of 75.6°F, superheat (SH) of 8.11, and subcooling (SC) of 225.7.
- HVACWork status not resolved
Photograph shows a heavily rusted GE condenser fan motor (model R201BS, 1/6 HP, 1500 RPM, 208-230V, 60 Hz, single phase) removed from equipment and lying on grass, with visible corrosion across the motor housing.