HVAC Diagnostic Service — and labor
- HVAC
On April 15, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 12760 Spanish Village Drive, Bridgeton, MO 63044.
- Record date
Documented details
- Outcome: Paid in full
Available findings
- HVACCompleted work$219
Performed residential diagnostic service with residential labor at the Bridgeton property.
- HVACWork status not resolved
Photograph shows the interior of an open HVAC air handler cabinet with visible ice/frost accumulation on what appears to be the evaporator coil or condensate area, along with black rubber hoses, wiring, a black plastic component (possibly a condensate trap or pressure switch), and a white PVC drain line at the bottom.
- HVACWork status not resolved
Photograph shows an outdoor air conditioning condenser unit mounted on a concrete pad, with insulated refrigerant suction line and copper liquid line connected at the service valves; multiple safety warning labels are visible on the unit cabinet.
- HVACWork status not resolved
Photograph shows a Daikin Comfort Technologies forced air furnace data plate, model GR9S800603BNAA, serial 2510119309, rated 60,000 BTU/hr input (natural gas or LP), 48,000 BTU/hr output, 115V/1-phase/60Hz, AHRI Certified.
- HVACWork status not resolved
Photograph shows a ThermoPro digital thermometer reading approximately 117°F being held near sheet metal HVAC ductwork in what appears to be a basement or utility space; a 'Detector Dead Stop' magnetic field indicator sticker is visible on the duct face.
- HVACWork status not resolved
0259F00303, REV A) mounted and wired, with multiple colored wire harnesses connected to labeled terminals including LINE-H, XFMR-H, ACC-H, and EAC-H
- HVACWork status not resolved
Photograph shows a live testo 557s refrigeration app reading for an R32 system: vapor pressure 121.0 psi (saturation temp 40.0°F), liquid pressure 261.1 psi (saturation temp 85.1°F), suction line temp 32.0°F, liquid line temp 75.4°F, subcooling 9.7°F, and superheat displayed as invalid (xxx).
- HVACWork status not resolved
Photograph shows a Testo digital refrigerant manifold gauge displaying R454B system readings: low-side pressure 118.1 LP psi, high-side pressure 250.5 HP psi, evaporator temperature 45.1°F, condenser outlet 87.5°F, T1 32.0°F, T2 74.8°F, superheat reading invalid (XXX), and subcooling 12.7°F.
- HVACWork status not resolved
Maintenance request submitted reporting AC not working
- HVACWork status not resolved
Photograph shows a handheld digital thermometer displaying 59°F held in an attic or crawl space area with visible flexible HVAC ductwork and wood framing in the background.
- HVACWork status not resolved