HVAC Repair Invoice — Blower motor + OEM circuit board replaced
- HVAC
- Plumbing
- Sewer
On September 1, 2026, Arch Air Services documented HVAC, Plumbing, and Sewer at 1286 Summergate Parkway, St. Peters, MO 63303.
- Record date
Available findings
- HVACCompleted work$2,101
Replaced OEM split-phase blower motor (bad windings), cleaned blower wheel, and replaced main OEM circuit board; outdoor unit was dirty and an A/C tune-up was recommended but not charged.
- HVACWork status not resolved
Photograph shows an outdoor air conditioning condenser unit on a concrete pad with weeds and vegetation growing around and through the unit's base and grille.
- PlumbingWork status not resolved
Photograph shows a large-diameter galvanized metal elbow drain pipe, a vertical lighter-colored pipe (PVC or plastic), and a horizontal galvanized pipe, all located in a basement or crawl space area with exposed wood framing.
- HVACWork status not resolved
- HVACWork status not resolved
Photograph shows a utility room with a large furnace/air handler unit on the left, a wall-mounted compact heating appliance in the center, and associated ductwork and piping running overhead.
- HVACWork status not resolved
Photograph shows the interior of an HVAC unit with access panel open, revealing a control board with multiple colored wires, and significant rust/corrosion staining at the base of the unit.
- HVACWork status not resolved
Photograph shows a squirrel-cage blower wheel (fan assembly) removed from an HVAC unit, with visible dust and debris accumulation on the blades.
- HVACWork status not resolved
Photograph shows a high-efficiency furnace with white PVC flue/exhaust pipes installed in a basement utility area, alongside adjacent mechanical equipment and overhead ductwork.
- HVACWork status not resolved
Photograph shows a squirrel-cage blower wheel (centrifugal fan) removed from an HVAC unit and placed on a blue surface.
- HVACWork status not resolved
Photograph shows an outdoor air conditioning condenser unit mounted on a concrete pad, with darkened/dirty coil fins visible on the exterior, a fan on top, and electrical conduit running to a disconnect box mounted on the building wall above.
- SewerWork status not resolved
Photograph shows a dark, circular pipe or drain interior viewed from above or from a camera perspective, with minimal detail visible due to low lighting.
- HVACWork status not resolved
a concrete block wall is visible in the background
- HVACWork status not resolved
Photograph shows an HVAC blower wheel (squirrel cage fan) with severe accumulation of dust, dirt, and debris coating the blades and center hub, indicating significant lack of maintenance.
- HVACWork status not resolved
Photograph shows an outdoor air conditioning condenser unit on a concrete pad with visibly dirty/debris-laden coil fins and weeds growing around the base.