Highlights selected from 2 documented records for this property.
- HVAC · AC condenser coil replaced with new Guardian coil · Apr 2026
- HVAC · Refrigerant recharged and AC system flushed and brazed · Apr 2026
- HVAC · Residential HVAC diagnostic service performed · Mar 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 2 documented records for 131 Elkan Avenue, Ferguson, MO 63135, dated in March 2026. The amount summary includes $3,164 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Diagnostic Service — Residential diagnostic service, no charge
- HVAC
Built from Housecall Pro data
- HVACResidential diagnostic service was performed at 131 Elkan Avenue, Ferguson, Missouri.
- HVACPhotograph shows an outdoor air conditioning condenser unit mounted on a concrete pad adjacent to a white stucco building exterior, with refrigerant line set and electrical wiring running up the wall to a disconnect box and wall penetration.
- HVACPhotograph shows an outdoor HVAC condenser unit on a concrete pad with visibly dirty, debris-laden coil fins and louvered cabinet, surrounded by mulch and leaf litter; electrical conduit is visible at the top.
- HVACPhotograph shows an outdoor HVAC condenser unit data plate: Model RAC13L24B24SA, Serial W2H0073335, R-410A refrigerant, factory charge 3 lbs 7 oz, 208-230V 1PH 60HZ, compressor 8.4 RLA / 53.0 LRA, cooling fan 0.8 FLA 1/8 HP, minimum circuit ampacity 11.4, max fuse/breaker 15; total charge fields are blank.
- HVACPhotograph shows an outdoor HVAC condenser unit with a dented and deformed metal cabinet grille, visibly dirty and debris-laden condenser coil fins visible through the grille openings, moisture on the cabinet surface, and leaf/debris accumulation at the base.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Condenser Coil Service — Guardian condenser AC coil supplied
- HVAC
Built from Housecall Pro data
- $3,164HVACSupplied a Guardian condenser AC coil with 6 hours of labor, miscellaneous AC materials (nitrogen, brazing rod, copper elbows and couplings, vacuum pump, recovery, flush) and 4 units of 410-A refrigerant.
- $3,164HVAC
- HVACPhotograph shows the exterior side of an outdoor HVAC condenser unit with condenser coil fins and frame channels heavily packed with dirt, lint, and debris; a hand-drawn upward arrow is marked on the metal frame rail.