Hi, I'm 1318 Barkman Drive. I only speak from this property's source-backed records — 3 documents from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.
1318 Barkman Drive
Across 3 records on this home
Completed work
Invoices and paid receipts
Estimated · not confirmed
Quotes, estimates, and other amounts not confirmed as performed
Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 3 documented records
Fresh House Property Summary
Highlights selected from 3 documented records for this property.
- HVAC · Condenser fan motor and capacitor serviced on a diagnostic visit · Sep 2025
- HVAC · Seasonal heating maintenance performed under a residential plan · Jan 2026
- HVAC · Air conditioning maintenance completed under residential maintenance plan · Mar 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 3 documented records for 1318 Barkman Drive, St. Louis, MO 63146, dated from September 2025 through January 2026. The amount summary includes $954.15 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Maintenance — Condenser fan motor and capacitor
- HVAC
Built from Housecall Pro data
- $594HVACDiagnostic trip performed and condenser fan motor and capacitor service completed.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Maintenance Plan — Seasonal heating maintenance
- HVAC
Built from Housecall Pro data
- $360HVACMaintenance plan provided with seasonal heating maintenance performed.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Maintenance Invoice — Air conditioning maintenance plan visit
- HVAC
Built from Housecall Pro data
- HVACAir conditioning maintenance performed under the Residential Maintenance Plan at 1318 Barkman Drive.
- HVACPhotograph shows an HVAC air handler or furnace unit with panels removed, exposing internal wiring, control components, and insulated refrigerant/gas lines; service tools are visible on the floor nearby.
- HVACPhotograph shows a UEi PDT655 digital thermometer clipped to a dark HVAC duct or plenum at ceiling level, displaying a temperature reading of 44°F.
- HVACPhotograph shows a testo 557s live refrigeration diagnostic screen for an R22 system: suction pressure 61.3 psi (vapor saturation temp 34.8°F), liquid pressure 148.0 psi (liquid saturation temp 81.8°F), suction line temperature 32.0°F, liquid line temperature 79.1°F, subcooling 2.7°F, and superheat reading invalid (xxx).
- HVACPhotograph shows a UEi PDT650 pocket thermometer clipped to a sheet metal HVAC supply duct displaying a temperature reading of 69.2°F, with a round flexible duct branch and a filter access panel visible in the background.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.