- HVAC · New 2-ton AC condensing unit and coil installed with full electrical and sheet metal work · May 2024$5.9k
- HVAC · Low-temperature cut-off added to the outdoor unit · Jul 2024
- HVAC · Return vent under furnace was painted over, causing iced coil and no airflow · May 2024
- HVAC · System checked and found operating within normal charge and airflow range · Jul 2024
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 9 documented records for 1320 Academy Avenue, St. Louis, MO 63113, dated from March 2024 through July 2024. The amount summary includes $13,905.85 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Service Call — Old AC with R22 leak; replacement advised
- HVAC
Built from Housecall Pro data
- $214HVACService call for AC not producing cold air; system is old with an R22 refrigerant leak, and replacement was recommended to the owner.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Condenser and Coil Replacement — 2-ton R410A condenser and coil
- HVAC
Built from Housecall Pro data
- $6,187HVACInstalled a 2 ton R410A condensing unit and cased coil, with fused disconnect, electrical whip, pad, sheet metal work, line set flush and pressure test, and readjusted the furnace gas line with drip leg and shut off valve; crane used to swap the condenser.
Documented warrantyfive-year / ten-year / twenty-yearFrom invoiceView details
What this warranty covers
- parts
· source
“manufacturer five-year parts warranty”
- labor
· source
“Contractor offers a five-year labor warranty on all new equipment installed”
- compressor
· source
“ten-year compressor warranty”
- parts
· source
“Once the equipment has been properly registered, the five-year manufacturer parts warranty becomes a ten-year parts warranty.”
- heat exchanger
· source
“a twenty-year heat exchanger warranty”
Coverage based on an invoice. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Ductwork — 2-ton condenser and coil installed
- HVAC
Built from Housecall Pro data
- $5,875HVACInstalled a 2 ton R410A condensing unit and cased coil (13 SEER) including fused disconnect, electrical whip, pad, sheet metal work to adapt coil to ductwork, and line set flush and pressure test; furnace gas line readjusted with drip leg.
Documented warrantyfive-year / ten-year / twenty-yearFrom invoiceView details
What this warranty covers
- parts
· source
“All equipment installed by Contractor comes with a manufacturer five-year parts warranty”
- labor
· source
“Contractor offers a five-year labor warranty on all new equipment installed by contractor.”
- compressor
· source
“ten-year compressor warranty”
- parts
· source
“Once the equipment has been properly registered, the five-year manufacturer parts warranty becomes a ten-year parts warranty.”
- heat exchanger
· source
“a twenty-year heat exchanger warranty”
Coverage based on an invoice. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — Iced coil from paint-blocked return vent
- HVAC
Built from Housecall Pro data
- $152HVACService call for no airflow in master bedroom; found ice on the coil because the return vent under the furnace was painted over, cleaned the return grill, and advised keeping the thermostat at 72 degrees.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — Low refrigerant, extremely dirty filter
- HVAC
Built from Housecall Pro data
- $152HVACNormal hours service call to check system and temperatures at vents; system was a little low in refrigerant, an extremely dirty filter was found, and no refrigerant leaks were detected from the condensing unit or furnace coil.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Repair Service Call — Loose high voltage wire fixed; R22 added
- HVAC
Built from Housecall Pro data
- $327HVACService call for AC not cooling: found condensing unit not running due to an undone high voltage wire, fixed the wire, system came on, and added 1 lb of R22 refrigerant.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Lineset Replacement — Lineset replaced, coil replaced under
- HVAC
Built from Housecall Pro data
- $1,000HVACReplaced coil under warranty and replaced lineset from condensing unit to coil.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — Systems normal; service call waived
- HVAC
Built from Housecall Pro data
- HVACService call for tenant report of unit not working; all systems found functioning as intended, with charge, air flow and temperature drop within normal operating range.
- HVACPhotograph shows multiple black cables and wires running along the exterior brick facade of a multi-story building, attached at various points, with a utility pole and associated overhead lines visible in the upper portion of the image.
- HVACR-410A non-TXV system diagnostic shows current superheat of 20° against a recommended superheat of 22°; system status is Correct Charge.
- HVACPhotograph shows an orange digital thermometer (range -40° to 482°F / -40° to 250°C) being used to measure temperature inside what appears to be HVAC ductwork; the LCD display reading is not clearly legible due to glare.
- HVACPhotograph shows a digital thermometer (ET05, range -40° to 482°F) displaying a temperature reading near what appears to be a duct or ceiling surface, with flexible corrugated ductwork visible in the background.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Invoice — Low temp cut off added to outdoor unit
- HVAC
Built from Housecall Pro data
- HVACAdded a low temp cut off to the outdoor unit.
Only original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.