HVAC Maintenance Invoice — Heating maintenance, maintenance plan

  • HVAC

On October 20, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 1323 Cheshire Lane, Webster Groves, MO 63119.

Record date

Available findings

  • HVACCompleted work

    Heating maintenance performed under the Residential Maintenance Plan.

  • HVACWork status not resolved

    Photograph shows a Fasco brand blower motor (model J238-112) with a data plate reading 120V, 60Hz, 1.2FLA, 3250RPM, 1.5LRRA, T.P.L. B, with UL listing numbers E64080 and E48562, installed in what appears to be an HVAC air handler or furnace blower assembly.

  • HVACWork status not resolved

    Photograph shows a 20x25x1 air filter leaning against HVAC equipment in a basement mechanical room; the filter media appears visibly dirty/gray, suggesting it is due for replacement.

  • HVACWork status not resolved

    Photograph shows a UEI Test Instruments EM152 digital manometer displaying a reading of 3.73, being used in a mechanical space with visible metal pipes and conduit.

  • HVACWork status not resolved

    Photograph shows a squirrel-cage blower wheel with heavy accumulation of dust and debris coating the blades and housing surfaces, with dark streaking visible between the vanes.

  • HVACWork status not resolved

    Photograph shows a pipe inspection camera monitor displaying the interior of a pipe with visible debris accumulation, deteriorated material, and possible organic buildup along the pipe walls and between structural ribs; camera sensor reads 114°F.

  • HVACWork status not resolved

    Photograph shows a sewer/drain pipe camera monitor screen displaying the interior of a pipe with visible debris or sediment buildup on the pipe floor; camera reads 105°F ambient temperature and timestamp of 6-19-26 at 11:07.

  • HVACWork status not resolved

    Photograph shows a yellow SPK2 digital thermometer with a metal probe inserted into a sheet metal HVAC duct or plenum, with galvanized ductwork and an HVAC unit cabinet visible in the background.

  • HVACWork status not resolved

    Photograph shows a person inserting a new 20x25x1 air filter into a metal HVAC air handler unit, with the filter access panel open and PVC condensate drain piping visible nearby.

  • HVACWork status not resolved

    Photograph shows the interior of a metal appliance enclosure (likely a furnace or water heater) with a tool pointing at a small metal component near the base; visible rust/orange-brown staining is present adjacent to the component, and partial hazard warning labels are visible at the bottom of the unit.

  • UnclassifiedWork status not resolved

    Photograph shows a yellow SPK2 handheld thermometer displaying 168°F being held against the underside of a floor structure in a basement or crawl space, with metal joists/decking, concrete floor, support columns, and stored items visible in the background.

  • HVACWork status not resolved

    Photograph shows a UEI EM152 digital manometer displaying a reading of 35.0, being used near what appears to be a furnace or HVAC appliance in a basement utility area.

  • HVACWork status not resolved