  • HVAC
    HVAC · Refrigerant recharged with 6 pounds of R-410A added · Jul 2026
  • HVAC
    HVAC · Rooftop condenser coil fins visibly packed with debris and lint · 2026
  • HVAC
    HVAC · Rooftop unit interior shows heavily soiled blower wheel · 2026
Ask this homePowered by Fresh House property intelligence®
THE HOME

Hi, I'm 13491 Olive Boulevard. I only speak from this property's source-backed records — 3 documents from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.

ASK ME ABOUT

RECORD SUMMARY

3 documented events
Contributed by: 1 contributor
First documented event: Jun 2026
Latest documented event: Jul 2026
First added to Fresh House: Nov 2026
Fresh House

Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.

DOCUMENTED HISTORY

This page contains 3 documented records for 13491 Olive Boulevard, Chesterfield, MO 63017, dated from June 2026 through July 2026. The amount summary includes $1,619 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.

HVAC

HVAC Diagnostic Service — Commercial diagnostic, return trip

Document dated Jun 29, 2026Uploaded Nov 9, 20267 files
Documented from uploaded report
Property Professional Uploaded
By
JLM HEATING AND AIR CONDITIONINGdocumented HVAC at 13491 Olive Boulevard, Chesterfield, MO 63017.
Scope
  • HVAC
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $489
  • HVACDiagnostic service, return trip, and two hours of commercial labor performed during normal business hours.
    $489
  • HVACPhotograph shows a close-up view of an HVAC air filter or return air grille with metal louvers; the filter media behind the slats is heavily loaded with dark gray dust, lint, and particulate debris, indicating a significantly clogged filter in need of replacement.
  • HVACPhotograph shows a rooftop HVAC condenser unit with louvered coil guards; condenser fins appear darkened with debris accumulation, and the metal roof curb below exhibits visible rust and corrosion staining.
Attached photo 1HVAC
Attached photo 2HVAC
Attached photo 3HVAC
Attached photo 4HVAC
+2

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Service Invoice — No-charge service visit

Document dated Jul 1, 2026Uploaded Nov 9, 20261 file
Documented from uploaded report
Property Professional Uploaded
By
JLM HEATING AND AIR CONDITIONINGdocumented HVAC at 13491 Olive Boulevard, Chesterfield, MO 63017.
Scope
  • HVAC
Contributor
worked on or inspected it

Built from Housecall Pro data

Only original contributor can modify this entry

Create an account to manage your contributions over time

HVAC

HVAC Diagnostic and Refrigerant Service — 6 lbs R-410A refrigerant

Document dated Jul 30, 2026Uploaded Nov 9, 202611 files
Documented from uploaded report
Property Professional Uploaded
By
JLM HEATING AND AIR CONDITIONINGdocumented HVAC at 13491 Olive Boulevard, Chesterfield, MO 63017.
Scope
  • HVAC
Outcome
Paid in full
Contributor
worked on or inspected it

Built from Housecall Pro data

Total documented value on this timeline entry: $1,130
  • HVACPerformed commercial overtime diagnostic and 2 hours of overtime labor, and added 6 pounds of additional R-410A refrigerant.
    $1,130
  • HVACFieldpiece app refrigerant side measurements show R-410A system with suction pressure 123.8 psig, liquid pressure 343.4 psig, actual superheat 27.3°F, and actual subcooling 3.7°F.
  • HVACPhotograph shows Fieldpiece app screen displaying live R-410A refrigerant measurements: suction pressure 126.9 psig, suction temperature 61.7°F, vapor saturation 43.6°F, actual superheat 18.1°F; liquid pressure 364.7 psig, liquid temperature 91.5°F, liquid saturation 109.6°F, actual subcooling 18.1°F, discharge pressure 364.7 psig.
Attached photo 1HVAC
Attached photo 2HVAC
Attached photo 3HVAC
Attached photo 4HVAC
+6

Only original contributor can modify this entry

Create an account to manage your contributions over time

Only the original contributor can modify this entry · Create an account to manage your contributions over time.

Add inspections, repairs, appraisals,
or anything that shaped this property.

PROPERTY COVERAGE

HVAC
✓ documented
Home Inspection
undocumented
Roof
undocumented
Plumbing
undocumented
Sewer
undocumented
Foundation
undocumented
Mold
undocumented
Electrical
undocumented
Pest
undocumented
Radon
undocumented
Appraisals
undocumented
Windows
undocumented

Nearby properties with documented history