- HVAC · Evaporator coil replaced and refrigerant system recharged · Jul 2026
- HVAC · New filter dryer installed and system vacuumed down · Jul 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 1 documented record for 1397 Timothy Drive, Arnold, MO 63010, dated in July 2026. The amount summary includes $1,645 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Evaporator Coil Replacement — Evaporator coil replaced
- HVAC
Built from Housecall Pro data
- $1,645HVACReplaced evaporator coil, including new filter, dryer, vacuum down to 300 microns and recharging of the system.
- HVACPhotograph shows a Fieldpiece MG44 Wireless Vacuum Gauge with an active LCD reading, alongside HVAC refrigerant charging hoses (yellow, red, blue/black, rated 4000 psi) and a digital manifold gauge set, indicating an HVAC refrigerant system service or evacuation in progress.
- HVACPhotograph shows a Testo 557 digital manifold gauge connected to an outdoor condenser unit, displaying R410A refrigerant readings: superheat (SH) 8.2°F, subcooling (SC) 4.1°F, low-side pressure 146.9 psi, and high-side pressure 316.5 psi.
- HVACPhotograph shows a furnace unit (dark gray metal cabinet) installed in a utility/mechanical space, with a galvanized sheet-metal supply plenum above, black flue/exhaust piping exiting the top of the unit, flexible conduit and wiring running along the cabinet, a white electrical junction box mounted on the adjacent wall stud, black iron gas supply piping with shutoff valve at lower left, and an open floor drain or condensate drain port visible at the base of the unit.
- HVACPhotograph shows a basement furnace/air handler unit with a galvanized metal flue vent pipe routed upward and horizontally, black iron gas supply piping to the left, and a service/maintenance date sticker affixed to the right side panel; the flue pipe exterior shows dust accumulation.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.