Hi, I'm 1405 Fenway Drive. I only speak from this property's source-backed records — 7 documents from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.
1405 Fenway Drive
Across 7 records on this home
Completed work
Invoices and paid receipts
Estimated · not confirmed
Quotes, estimates, and other amounts not confirmed as performed
Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 7 documented records
Fresh House Property Summary
Highlights selected from 7 documented records for this property.
- HVAC · Two complete HVAC systems replaced with new Carrier units and thermostats · Sep 2024$25k
- Plumbing · Gas line rerouted to stove with new black iron and shutoff · Feb 2025
- HVAC · Both HVAC systems serviced with refrigerant added before replacement · Apr 2024
- HVAC · Both furnaces received a tune-up in late 2025 · Dec 2025
- HVAC · Both air conditioners received a tune-up in spring 2026 · Apr 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 7 documented records for 1405 Fenway Drive, Fenton, MO 63026, dated from March 2024 through April 2026. The amount summary includes $27,850 in completed work across HVAC and Plumbing; appraisal values and permit-declared valuations are excluded.
HVAC Tune-Up — Two A/C tune ups
- HVAC
Built from Housecall Pro data
- $198HVACPerformed two A/C tune ups at 1405 Fenway Drive, Fenton, Missouri.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC System Check — 4 ton unit 2.5 lbs low on R22
- HVAC
Built from Housecall Pro data
- $625HVACChecked both systems; the 4 ton unit was 2.5 lbs low on R22 but mechanically working well, 2.5 lbs of R-22 were supplied, and the 2 ton unit's valves are starting to allow refrigerant through, with both old units near end of life.
- HVAC2TTB0048A1000AA, Serial No. 40552TE3F) with a manufacturer date of 01/2004, rated 200/230V, using HCFC-22 refrigerant (6 lbs 13 oz), assembled in USA
- HVACPhotograph shows a Fieldpiece SMAN Refrigerant Manifold + Micron Gauge connected to an outdoor AC condenser, displaying a high-side pressure of 207.5 Psig, subcooling (SC) of 24.5, and liquid-line saturation temperature (LSAT) of 103.8, with additional readings of 418 (SLT) and 793 visible on the left panel.
- HVACPhotograph shows a green refrigerant cylinder with a yellow hose connected, resting on grass beside an open hard-shell case containing a digital refrigerant charging scale (CPS brand).
- HVACPhotograph shows a CPS electronic refrigerant scale displaying a reading of 1 lb 12.00 oz, placed in its carrying case on a grass surface.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Replacement — Two Carrier furnace/AC systems, 2 and 4 ton
- HVAC
Built from Housecall Pro data
- $24,847HVACInstalled two Carrier systems (2 ton and 4 ton, 16 SEER, 80% AFUE two-stage furnaces with TXV cased coils), replaced two condenser wall brackets, and included new pad, disconnect, drain lines, flue, gas piping, and two WiFi thermostats.
Documented warrantyfive-year / ten-year / twenty-yearFrom invoiceView details
What this warranty covers
- parts
· source
“manufacturer five-year parts warranty”
- compressor
· source
“ten-year compressor warranty”
- parts
· source
“Once the equipment has been properly registered, the five-year manufacturer parts warranty becomes a ten-year parts warranty.”
- labor
· source
“Contractor offers a ten-year labor warranty on all new equipment installed by contractor.”
- heat exchanger
· source
“a twenty-year heat exchanger warranty”
Coverage based on an invoice. Fresh House records the terms stated on the document and does not determine which tier applies here. Ownership, occupancy, service territory, ordered options, start date and exclusions all affect coverage.
Only original contributor can modify this entry
Create an account to manage your contributions over time
Plumbing Gas Line Installation — Gas line moved to stove, new shut off
- Plumbing
Built from Housecall Pro data
- $1,982PlumbingInstalled gas line to new location by cutting the 1" copper gas line, brazing a new T for a 3/4 line to the stove, and running black iron from the cabinet with a new safety shut off.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Maintenance Invoice — HVAC maintenance on 2 systems
- HVAC
Built from Housecall Pro data
- HVACHVAC maintenance performed on two systems, fall or spring general maintenance, per system.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Furnace Tune-Up — Two furnace tune-ups
- HVAC
Built from Housecall Pro data
- $198HVACPerformed furnace tune-ups on two furnaces.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Tune Up — Two A/C tune ups performed
- HVAC
Built from Housecall Pro data
- $198HVACPerformed two A/C tune ups at 1405 Fenway Drive, Fenton, Missouri.
Only original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.