Document (07/14/2026)
- Electrical
- Foundation
- HVAC
- Home Inspection
- Pest
- Plumbing
- Roof
- Windows
On July 14, 2026, Greensmith Home Inspection llc documented Electrical, Foundation, HVAC, and 5 other topics at 157 Cardow Drive, O'Fallon, MO 63368.
- Record date
Available findings
- PestWork status not resolved
Visual WDI inspection of SFR/Attached Garage at 157 Cardow Drive found no visible evidence of wood destroying insects; no action or treatment recommended.
- Home InspectionWork status not resolved
Whole-home inspection of new construction single-family home at 157 Cardow Drive, O'Fallon, MO; home described as in excellent condition with no structural issues, but 13 deficiencies noted across site, garage, structure, HVAC, plumbing, electrical, windows, and interior systems.
- ElectricalWork status not resolved
Three dining room outlets were without power despite checking breakers and all light switch configurations; all other visible outlets operational and grounded correctly; 200-amp Eaton service panel in garage with basement sub-panel.
- HVACWork status not resolved
Missing HVAC floor vents require replacement; Bryant 78,000 BTU forced-air gas furnace (mfgd 2025) and Carrier 3.5-ton condenser (mfgd 2025) appear functional; gas fireplace could not be tested due to missing remote and needs proper trim.
- PlumbingWork status not resolved
Water heater expansion tank must be strapped or supported — currently hanging freely on the water supply pipe, risking stress on fittings and leaks; Bradford White 50-gallon electric water heater (mfgd 2025) otherwise appears functional.
- FoundationWork status not resolved
Rust observed on basement support beam bottom plates requires removal; poured concrete foundation and basement walls show no deficiencies; site grading bare spots need re-seeding; garage south wall sheetrock section incomplete, exposing risk of nail contact.
- RoofWork status not resolved
Architectural shingle roof inspected via drone; condition satisfactory with no defects observed; soffit, ridge vents, metal flashings, gutters, and downspouts all satisfactory.
- WindowsWork status not resolved
Inside window trim is not properly squared; exterior vinyl windows are satisfactory in condition.