Record 1Public property record

HVAC Maintenance Plan Visit — Residential maintenance plan visit #1

  • HVAC

On April 16, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 1597 Fairmount Avenue, St. Louis, MO 63139.

Record date

Available findings

  • HVACCompleted work

    Visit #1 under the Residential Maintenance Plan was performed at the service address.

Record 2Public property record

HVAC Maintenance Plan Visit — Maintenance plan visit #2

  • HVAC

On October 15, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 1597 Fairmount Avenue, St. Louis, MO 63139.

Record date

Available findings

  • HVACCompleted work

    Visit #2 of the Residential Maintenance Plan was performed at the service address.

  • HVACWork status not resolved

    Photograph shows a furnace igniter electrode with a white ceramic insulator body, metal mounting flange, spade terminal connector at the top, and an L-shaped metal electrode rod at the bottom, resting on a concrete surface.

  • HVACWork status not resolved

    Photograph shows a yellow SPK2 handheld thermometer displaying 72.9°F, held against the surface of a metal HVAC duct or air handler cabinet.

  • HVACWork status not resolved

    7158-0164E, Class B, 115V, 3000 RPM, 60 Hz) mounted in HVAC equipment, with visible surface rust/corrosion on the metal housing

  • HVACWork status not resolved

    Photograph shows the interior of a gas furnace with the access panel removed, revealing the draft inducer blower motor, gas valve with manual shutoff, black gas supply piping, pressure switch, multi-colored wiring harnesses, burner manifold assembly, and visible rust/corrosion staining on the sheet metal cabinet near the inducer housing.

  • HVACWork status not resolved

    Photograph shows a handheld SPK2 digital thermometer displaying a reading of 119.5°F, placed on a metal surface.

  • HVACWork status not resolved

    Photograph shows open gas furnace interior with visible rust/brown staining streaking from the flue collar and draft inducer area, significant dust and debris accumulation on the burner shelf, a gas valve with multi-color wiring, pressure switch, and burner tubes; a 'NOTICE: CLEAN COILS USING WATER ONLY' label is visible on the cabinet.

  • HVACWork status not resolved

    Photograph shows the interior of a gas furnace with multiple clamshell heat exchanger cells, an inducer/draft motor assembly, gas burner manifold, and associated wiring — all surfaces are heavily coated with dust and debris accumulation.

  • HVACWork status not resolved

    Photograph shows the open interior compartment of a furnace, revealing a control/ignition circuit board (labeled 'Intelli-Ignition') with multiple multi-colored wires routed in a disorganized manner throughout the cabinet.

  • HVACWork status not resolved

    Photograph shows a visibly dirty, dust-laden pleated air filter (approximately 19.5 x 24.5 x 0.875 inches) removed from a furnace or air handler unit in a utility/basement area.

  • HVACWork status not resolved

    Photograph shows a heavily corroded gas valve and surrounding metal surfaces inside a furnace cabinet, with extensive rust staining and surface corrosion visible on the valve body and adjacent sheet metal panel.

  • HVACWork status not resolved

    Photograph shows a sheet-metal HVAC condensate drain pan with heavy brownish-orange rust staining and mineral/scale deposits across the interior surface, indicating prior or recurring standing water accumulation.

  • HVACWork status not resolved