- HVAC · Furnace and AC inspected, cleaned, and serviced · Jun 2026
- HVAC · AC compressor replacement estimated but not confirmed done · Jun 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 2 documented records for 1629 Walpole Drive, Chesterfield, MO 63017, dated in June 2026. The amount summary includes $290 in completed work across HVAC, $2,767 in estimates; appraisal values and permit-declared valuations are excluded.
HVAC Inspection and Maintenance — Furnace and A/C inspection
- HVAC
Built from Housecall Pro data
- $290HVACPerformed furnace inspection and cleaning (checked furnace operation, cleaned ignition components, checked heat exchanger and motor outputs) and air conditioning inspection and maintenance (checked operation, cleaned coils, checked refrigerant charge, contactor, capacitor and motor outputs).
- HVACPhotograph shows an HVAC blower wheel (squirrel cage fan) with heavy accumulation of dust, dirt, and debris coating all blades and the hub, indicating significant lack of maintenance or filter bypass.
- HVACPhotograph shows a Rheem outdoor condenser unit (Model DAGN-024JN, Serial W271633913, manufactured 07/2016) with data plate indicating 208/230V single-phase, R410A refrigerant, and 67.8 oz factory charge.
- HVACPhotograph shows the data plate of a Rheem outdoor condensing unit, model DAGN-024JN, serial W271633913, manufactured 07/2016, rated 208/230V single-phase, R410A refrigerant, factory charge 67.8 oz.
- HVACPhotograph shows a Fluke 116 True RMS Multimeter displaying a reading of 499 (dial set to AC voltage) being used on an HVAC unit with visible wiring, ductwork, and a supplemental electric heater fire hazard warning label.
- HVACPhotograph shows the interior of an open HVAC air handler with the access panel removed, revealing a heavily dust-laden blower motor (model label TWE024C140B0 partially visible), accumulated debris on the blower wheel and surrounding components, multiple wiring connections, and a capacitor
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Compressor Replacement Estimate — OEM compressor replacement
- HVAC
Option: Option #1 $2,767 (expired)
Built from Housecall Pro data
- $2,767HVACEstimate for replacing the OEM compressor at 1629 Walpole Drive, Unit D.
Only original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.