Record 1Public property record

HVAC Service Call — Overtime trip and 2 hours labor

  • HVAC

On July 29, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 1703 South 11th Street, St. Louis, MO 63104.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$390

    Overtime trip fee after 4:30 M-F, all day Saturday and Sunday, and 2 hours of residential non-member labor performed.

  • HVACWork status not resolved

    Photograph shows the interior of an electrical panel with heavily corroded, rusted, and heat-discolored bus bars alongside multiple circuit breaker slots; the metal bus bar components exhibit significant deterioration including pitting, rust, and apparent heat damage.

  • HVACWork status not resolved

    Photograph shows a large rectangular section of bathroom ceiling drywall cut open, exposing wood framing above, with visible water staining and discoloration on the surrounding ceiling surface.

  • HVACWork status not resolved

    Photograph shows the interior of an electrical panel or service entrance enclosure with multiple conductors — including a 4/0 AWG aluminum XHHW-2 service cable, bare copper stranded wires, orange-jacketed conductors, and smaller insulated wires — crowded at the line lugs; the enclosure surfaces show visible corrosion and oxidation.

  • HVACWork status not resolved

    Photograph shows the interior of an electrical panel with multiple circuit breakers exhibiting significant scorching, charring, and heat discoloration on the breaker bodies and surrounding panel enclosure, along with black, red, and purple wiring connected to the bus bar and breakers.

  • HVACWork status not resolved

    Photograph shows a Testo 557 digital manifold gauge connected to an HVAC system, displaying R410A refrigerant readings with low-side pressure of approximately 138.4 psig and high-side reading of approximately 00.0 psig, with saturation temperatures visible on the LCD display.

  • HVACWork status not resolved

    Photograph shows a severely burned and shattered circuit breaker in an electrical panel, with visible charring, melted plastic housing, and orange arc/burn damage; adjacent GE 30A breakers are also present.

  • HVACWork status not resolved

    Photograph shows GE electrical panel interior with a missing/displaced breaker leaving an open slot that exposes live bus bar components; visible corrosion and rust-colored discoloration on internal metal parts; multiple 30A and 20A GE breakers present with significant dirt and deterioration on breaker housings.

  • HVACWork status not resolved

    Photograph shows a pleated HVAC air filter with heavy dust and debris accumulation across the entire filter media surface, indicating the filter is well past its service life and requires replacement.

  • HVACWork status not resolved
  • HVACWork status not resolved

    Photograph shows a 3M Filtrete 1000 Allergen Defense air filter, size 14x20x1, rated MPR 1000, lasting up to 3 months, held in a home interior.