HVAC Maintenance Plan
- HVAC
On June 4, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 17039 Sandalwood Creek Drive, Wildwood, MO 63038.
- Record date
Documented details
- Outcome: Paid in full
Available findings
- HVACCompleted work$360
Maintenance plan provided for the HVAC system at the service address.
- HVACWork status not resolved
Photograph shows Fieldpiece app HVAC air-side measurements: return dry bulb 70.8°F / wet bulb 63.8°F / RH 68.2%; supply dry bulb 55.6°F / wet bulb 53.4°F / RH 87.0%; Delta T 15.2°F; system capacity not displayed.
- HVACWork status not resolved
Photograph shows the interior of an aged HVAC unit (furnace/air handler) with the access panel open, revealing a wiring harness wrapped in black electrical tape or a black connector, multiple colored wires (yellow, black, red, blue), terminal/limit switch components mounted on the interior panel, a partially visible data label sticker, and flexible metal conduit at the top; the sheet metal cabinet shows discoloration and signs of age.
- HVACWork status not resolved
Photograph shows an orange SPK2 digital thermometer displaying 117.9°F, resting on sheet metal ductwork or an air handler cabinet surface, with flexible metallic conduit and copper tubing visible nearby.
- HVACWork status not resolved
Fieldpiece app refrigerant side measurements for R-410A system show suction pressure 136.8 psig, liquid pressure 237.8 psig, actual superheat 10.0°F, and actual subcooling 0.9°F; air side diagnostics indicate supply dry bulb 55.4°F is close to target 54.8°F, indicating adequate airflow across the evaporator coil.
- HVACWork status not resolved
Photograph shows an orange SPK2 digital thermometer displaying a reading of 92.3°F, with what appears to be metal ductwork visible in the background.
- HVACWork status not resolved
Photograph shows interior of an air handler or blower compartment with a large bundle of multi-colored wires, a visibly corroded or dirty multi-pin electrical connector, a finned control module or resistor block, and a blower wheel heavily coated with dust and debris.
- HVACWork status not resolved
Photograph shows a Fieldpiece app screenshot of HVAC air-side measurements in Cool mode: return air reads 74.9°F dry bulb, 66.8°F wet bulb, 65.2% relative humidity, 62.5°F dew point, and 31.3 Btu/lbm enthalpy; supply-side readings are not yet linked and show no values; Delta T and system capacity are blank.
- UnclassifiedWork status not resolved
no property-related content is present
- HVACWork status not resolved
Photograph shows a large foil-faced HVAC duct with significant dark brown and black staining concentrated along the seams and lower face of the insulation wrap, visible in what appears to be a basement or utility space.
- HVACWork status not resolved
- UnclassifiedWork status not resolved
Photograph shows a smartphone calculator app screen displaying the calculation 14,082.12 ÷ 355.3 = 39.634449761; no property document or system information is present.