Hi, I'm 1722 Ridgeview Circle Drive. I only speak from this property's source-backed records — 2 documents from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.
1722 Ridgeview Circle Drive
Across 2 records on this home
Completed work
Invoices and paid receipts
Estimated · not confirmed
Quotes, estimates, and other amounts not confirmed as performed
Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 2 documented records
Fresh House Property Summary
Highlights selected from 2 documented records for this property.
- HVAC · Condenser fan motor and fan blade replaced on outdoor AC unit · Aug 2026
- HVAC · Condenser coil fins heavily packed with debris at time of service · 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 2 documented records for 1722 Ridgeview Circle Drive, Ballwin, MO 63021, dated in August 2026. The amount summary includes $1,500 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Work — Condenser fan blade and motor supplied
- HVAC
Built from Housecall Pro data
- $1,500HVACPerformed an overtime diagnostic and supplied a universal condenser fan blade and a condenser fan motor, with journeyman labor and a parts house after-hours opening.
- HVACPhotograph shows an outdoor HVAC condenser unit with a severely rusted and corroded fan guard/grille and fan motor housing; fan blades and wiring connections are visible through the guard.
- HVACPhotograph shows an outdoor HVAC condenser unit with a heavily rusted fan guard grille and fan motor hub; a cordless impact driver is resting on the guard, indicating service work in progress.
- HVACPhotograph shows an outdoor HVAC condenser unit with a heavily rusted fan guard/grille and severely corroded motor hub; fan blades are visible beneath the guard and the white cabinet shows rust staining at the base.
- HVACPhotograph shows an outdoor HVAC condenser unit with a heavily rusted fan guard grille and motor hub; a Milwaukee M18 cordless impact driver is resting on the grille, indicating active service work in progress.
- HVACPhotograph shows an outdoor AC condenser data plate: Model 38CK042300, Serial 1793E13096, factory charged with R-22 refrigerant (5.88 lbs / 2.67 kg), 208-230V single-phase 60Hz power supply, compressor RLA 18.2 / LRA 105.0, fan motor 1/4 HP, minimum circuit amps 24.2, max fuse 35A.
- HVACPhotograph shows the exterior condenser coil of an outdoor HVAC unit with the wire mesh guard heavily packed with dirt, dust, and fibrous debris, significantly restricting airflow through the coil fins; weeds are visible growing at the unit base.
- HVACPhotograph shows an outdoor AC condenser unit with significant rust and oxidation on the fan guard and fan hub, darkened/dirty condenser coil fins, and standing water and mud pooled on the ground immediately adjacent to the unit; refrigerant lines run from the unit to the house wall.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Fan Motor Estimate — Condenser fan motor and blade replacement
- HVAC
Option: Replace fan motor and blade $1,500 (expired)
Built from Housecall Pro data
- $1,500HVACEstimate for replacing the condenser fan motor and fan blade, including diagnostic, journeyman labor and parts house opening.
Only original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,