HVAC Diagnostic Service — Diagnostic service and mixed air sensor
- HVAC
On July 23, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 1935 Richardson Road, Arnold, MO 63010.
- Record date
Documented details
- Outcome: Paid in full
Available findings
- HVACCompleted work$515
Performed a commercial diagnostic service, supplied a mixed air sensor, and billed journeyman labor.
- HVACWork status not resolved
Photograph shows interior of an HVAC air handler with a visibly dark, heavily loaded pleated air filter installed; an evaporator coil is visible in the upper right, and orange and red wiring is bundled with a cable tie along the top of the cabinet.
- HVACWork status not resolved
Photograph shows the interior of an HVAC unit with a control board LCD display indicating a '#1 Sensor Fault' (or 'Sensor Fail') error code, surrounded by a dense wiring harness with multiple colored conductors bundled with zip ties.
- HVACWork status not resolved
Photograph shows the interior of an HVAC control panel with a green circuit board displaying '#1 Mixed Ai' on its LCD screen, multiple colored wiring harnesses, relay components, and labeled terminal connectors.
- HVACWork status not resolved
Photograph shows a visibly dirty 14x25x2 air filter installed in an HVAC air handler filter compartment; the filter frame is handwritten with the date 5-21-24 and the filter media appears heavily loaded with dust and debris.
- HVACWork status not resolved
Photograph shows several louvered supply/return air grilles mounted on the wall near the ceiling, along with what appears to be an additional duct or vent component on the left wall.
- HVACWork status not resolved
Photograph shows an outdoor HVAC unit data plate with model number ZE048H07B2C1AAA1A2, serial number N2H2776280, factory charged with R410A refrigerant, rated 208/230V, with compressor load current 13.7A RLA and handwritten markings '#2' and 'x2' on the unit casing.
- HVACWork status not resolved
Photograph shows the open control panel compartment of a commercial rooftop HVAC unit (cooling unit with gas heat, 208/230-3-60, SSE belt drive-motor), with the control board LCD displaying 'Cooling', multiple wiring harnesses, and an elementary wiring diagram affixed to the panel door.
- HVACWork status not resolved
Photograph shows the interior of an HVAC unit's control panel with a green circuit board, an LCD display reading '#1 / r Temp S', a navigation keypad (ENTER/CANCEL/JOY), and numerous multi-colored wiring harnesses routed through the compartment.
- HVACWork status not resolved
Photograph shows the interior base of an open rooftop HVAC package unit, revealing exposed electrical wiring (red, blue, black, and white conductors with wire nuts), a wire mesh screen, foil-taped sheet-metal ductwork with a square duct opening, a metal mounting bracket, and loose screws on the unit floor; the unit sits on a flat white roofing membrane.
- HVACWork status not resolved
Photograph shows an HVAC equipment control board (PCB) with an LCD display reading '#1 Failure,' indicating an active fault code, surrounded by a dense bundle of multi-colored wiring; a partial label at the bottom reads 'BELT DRIVE-MOTOR.'
- HVACWork status not resolved
Photograph shows a wall-mounted louvered supply or return air vent grille installed near the ceiling line on an interior white wall.
- HVACWork status not resolved
unit interior appears dusty
- HVACWork status not resolved
- HVACEstimate or proposed work$515