HVAC Maintenance — Condenser fan motor and capacitor
- HVAC
On August 27, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 1961 Wentzville Parkway, Wentzville, MO 63385.
- Record date
Documented details
- Outcome: Paid in full
Available findings
- HVACCompleted work$1,115
Diagnostic service performed with journeyman labor; condenser fan motor and capacitor supplied, plus extended trip and return trip.
- HVACWork status not resolved
Photograph shows a four-blade condenser fan assembly with heavy dust and dirt accumulation on all blades, visible rust/corrosion on the central motor shaft hub, and rust spots on multiple blade rivets, all within a dark circular fan shroud.
- HVACWork status not resolved
Photograph shows the top fan guard grille of an outdoor HVAC condenser unit with visible rust, corrosion, and paint chipping/peeling along the metal grille bars; a partially visible equipment label/sticker is present on the top panel beneath the grille.
- HVACWork status not resolved
Photograph shows a rooftop packaged HVAC unit with condenser coil fins heavily fouled by white mineral scale deposits and dark dirt/debris accumulation across the entire coil face; surface rust is visible on the base rail, and a pair of pliers rests on top of the unit.
- HVACWork status not resolved
Photograph shows a Fluke 323 True RMS Clamp Meter clamped around a wire on an HVAC compressor/condenser unit, displaying a reading of 17 AAC (AC amperes); copper refrigerant lines and wiring are visible in the background.
- HVACWork status not resolved
Photograph shows the open interior of an HVAC unit with a blower motor and wheel, gas valve, control board, contactor, and multi-colored wiring harnesses; significant debris accumulation, corrosion, and deterioration are visible on the unit floor, along with what appears to be degraded insulation or filter material.
- HVACWork status not resolved
Photograph shows interior of an open HVAC unit with blower motor, gas valve, burner assembly, and control board visible; heavy accumulation of dirt, deteriorated material, and corrosion throughout the cabinet interior, with dead insects on the floor in front of the unit.
- HVACWork status not resolved
Photograph shows manufacturer data plate on HVAC unit model GCS16-060-75-4T (S/N 5602G 08134), rated 75,000 BTUH input / 60,000 BTUH output heating, HCFC-22 refrigerant, 208/230V 3-phase electrical, min circuit ampacity 29A, max fuse/breaker 45A.
- HVACWork status not resolved
Fieldpiece app refrigerant-side measurements show R-22 system with suction pressure 64.9 psig, liquid pressure 161.0 psig, actual superheat 21.2°F, and actual subcooling 6.5°F.
- HVACWork status not resolved
Photograph shows a Filtrete MERV 8 Electrostatic Air Filter (20x25x2) installed in an air handler/furnace slot, with handwritten notation on the frame reading 'Replaced 6/22/25 FMS'.
- HVACWork status not resolved
rooftop mechanical equipment is visible in the background
- HVACEstimate or proposed work$1,115
- HVACWork status not resolved
Photograph shows a rooftop HVAC unit with the fan shroud panel open, exposing the fan blade and motor assembly inside the circular opening; a multimeter probe and pliers are visible on the unit surface, indicating active service or diagnostic work.
- HVACWork status not resolved