HVAC Capacitor Invoice — 40 + 5 Mfd dual capacitor supplied

  • HVAC

On July 13, 2026, ASSURED HEATING AND COOLING documented HVAC at 2011 Osage Street, St. Louis, MO 63118.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$155

    Supplied a 40 + 5 Mfd dual capacitor.

Record 2Public property record

HVAC Replacement Estimate — 3-ton 13 SEER A/C + 95% AFUE furnace

  • HVAC

On June 17, 2022, ASSURED HEATING AND COOLING documented HVAC at 2011 Osage Street, St. Louis, MO 63118.

Record date

Available findings

  • HVACEstimate or proposed work$9,789

    Estimate for Option #1: Full System 13 Seer 95% AFUE - 3 Ton 13 Seer, 95% AFUE 70,000 BTU, TXV Cased Coil (We Propose to install the following equipment in your home), Install Desc - Payment/Terms, Install Desc - Equipment Warranty (All equipment installed comes with a 5 year parts warranty, 10 year compressor), Install Desc - Description Full 90% Install (This proposal will include the following: New pad for condensing unit, fused); option declined.

Record 3Public property record

HVAC Condenser and Coil Installation — 2.5-ton 13 SEER condenser

  • HVAC

On June 22, 2022, ASSURED HEATING AND COOLING documented HVAC at 2011 Osage Street, St. Louis, MO 63118.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$5,652

    Installed Sure Comfort by Rheem 2.5 ton 13 SEER R410A condensing unit with TXV cased coil, including fused disconnect, electrical whip, pad, sheet metal adaptation to ductwork, and chemical flush and pressure test of line set.

Record 4Public property record

HVAC Furnace Replacement — 80% gas furnace installed

  • HVAC

On October 29, 2024, ASSURED HEATING AND COOLING documented HVAC at 2011 Osage Street, St. Louis, MO 63118.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$4,901

    Work performed: 80% Furnace Only 50,000/75,000 BTU (We propose to install the following equipment in listed unit); Equipment Warranty; Payment/Terms; Terms and Conditions; 4% card fee.

  • HVACWork status not resolved

    Photograph shows a gray metal HVAC air handler/furnace unit installed in a tight mechanical space, with foil HVAC tape (Shurtape AF 099 / 181B-FX) sealing the junction between unit sections and ductwork, a white PVC condensate or flue pipe visible to the right, and a California Proposition 65 warning label affixed to the cabinet.

  • HVACWork status not resolved

    Photograph shows a Sure-brand high-efficiency gas furnace installed in a basement mechanical room, with two white PVC intake/exhaust flue pipes (purple-primed joints) routed from the top of the unit, a yellow flexible gas connector on the left, and flexible metallic ductwork on the right.

  • HVACWork status not resolved

    Photograph shows a high-efficiency furnace with white PVC flue/exhaust and combustion-air intake pipes (purple primer visible at joints), a yellow flexible corrugated gas connector, and a galvanized sheet-metal duct with foil-taped junction above.

  • HVACWork status not resolved

    Photograph shows a gray metal air handler unit installed in a basement utility space, with flexible metallic conduit, a white PVC condensate drain line with purple-primed fitting, braided flexible refrigerant lines connected to red-capped service valves, foil-faced duct board plenum above, and a junction box mounted on the unit cabinet.

  • HVACWork status not resolved

    Photograph shows a white PVC drain-waste-vent pipe running vertically through a narrow wall cavity, transitioning through a 90-degree sweep elbow fitting with visible purple primer marks; the pipe and surrounding cavity are heavily coated in dust and cobwebs.

View 2011 Osage Street, St. Louis, MO 63118 on Fresh House