Hi, I'm 202 North Bemiston Avenue. I only speak from this property's source-backed records — 6 documents from 1 contributor. If there's no record, I'll tell you I don't know rather than guess. Every claim links to its source.
202 North Bemiston Avenue
Across 6 records on this home
Completed work
Invoices and paid receipts
Estimated · not confirmed
Quotes, estimates, and other amounts not confirmed as performed
Property History Report
Negotiate this home like you've seen its receipts. You have.
Free right now · built from this home's 6 documented records
Fresh House Property Summary
Highlights selected from 6 documented records for this property.
- HVAC · Electric water heater replaced with expansion tank and code upgrades · May 2024
- HVAC · Both furnaces tuned up and humidifier serviced · Jan 2025
- HVAC · Both A/C units received tune-ups · Apr 2024
- HVAC · Second-floor furnace roll-out safety tripped and reset · Dec 2022
- HVAC · Both outdoor AC units inspected and found operational · Apr 2022
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 6 documented records for 202 North Bemiston Avenue, Clayton, MO 63105, dated from April 2022 through January 2025. The amount summary includes $3,569.25 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Second Opinion — Both AC systems functioning; charge slightly low
- HVAC
Built from Housecall Pro data
- HVACPerformed a second opinion on a reported need for a new outdoor unit; both AC systems were found functioning, with system charge appearing slightly low but no heat load at the moment.
- HVACPhotograph shows an outdoor air conditioning condenser unit on a concrete pad with a digital manifold gauge set and refrigerant hoses connected to the service ports, and a clamp meter attached to the electrical wiring at the nearby disconnect box, indicating active refrigerant or diagnostic servicing in progress.
- HVACPhotograph shows an outdoor HVAC condenser unit with refrigerant manifold hoses connected to the service port, a Fluke 323 clamp meter displaying a reading of 47, and a visible tear in the suction line foam insulation with a teal-colored substance present at the breach.
- HVACPhotograph shows the lower section of an outdoor HVAC condenser unit with copper refrigerant lines, insulated suction line, and two red-capped Schrader service valve ports visible at the unit's refrigerant connection point.
HVAC
HVAC
HVAC
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — Roll out safety tripped; back draft melting
- HVAC
Built from Housecall Pro data
- $120HVACService call for no heat on 2nd floor unit: found unit off due to roll out safety, cleaned off and reset it; melting damage from back draft noted but no other problems found.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Furnace Tune-Up — Two furnace tune-ups
- HVAC
Built from Housecall Pro data
- $153HVACPerformed two furnace tune-ups at the service address, with a flyer/10% discount applied.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Tune Up — Two A/C tune ups
- HVAC
Built from Housecall Pro data
- $198HVACPerformed two A/C tune ups at 202 North Bemiston Avenue.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Water Heater Installation — 50/40 gallon electric water heater
- HVAC
Built from Housecall Pro data
- $2,900HVACInstalled a 50/40 gallon electric water heater, attached to existing copper lines with flex lines using the existing flue, including gas line, expansion tank and other code requirements.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Furnace Tune-Up — Furnace tune-up (2); water heater set to 140
- HVAC
Built from Housecall Pro data
- $198HVACFurnace tune-up performed on two units, hot water problems and humidifier inspected, cleaned and checked, T/M repaired, and water heater temperature turned to 140 with customer advised of water temperature changes.
Only original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.
Add inspections, repairs, appraisals,
or anything that shaped this home.