Complete public upload archive

Property records for 2045 Oak Drive, Arnold, MO 63010

All 2 public upload records returned by the Fresh House property feed are available across 1 server-rendered page. This page shows records 1 to 2.

Record details are source-backed where available. Permit status and descriptions repeat the publishing agency's data; they do not independently establish that work was completed.

Return to the property overview
Record 1Public property record

HVAC Air Conditioner Install — New air conditioner and evaporator

  • HVAC

On February 9, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 2045 Oak Drive, Arnold, MO 63010.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$2,800

    Installed new air conditioner and evaporator with a custom plenum to adapt to existing duct work, evacuated the line set, charged the system with the correct amount of refrigerant, and performed start up testing.

  • HVACWork status not resolved

    Photograph shows an aged outdoor air conditioning condenser unit with its top panel open and internal wiring/components exposed, mounted on a gravel pad against the exterior stucco wall; a second smaller HVAC unit is mounted on a bracket at the upper level, and an electrical disconnect box with conduit is visible on the wall adjacent to the main condenser.

  • HVACWork status not resolved

    Photograph shows an outdoor air conditioning condenser unit installed on a gravel bed adjacent to a white exterior wall, with two electrical disconnect boxes mounted on the wall nearby.

Record 2Public property record

HVAC Service Invoice — Contactor supplied, 2 lbs R-410A added

  • HVAC

On February 27, 2026, JLM HEATING AND AIR CONDITIONING documented HVAC at 2045 Oak Drive, Arnold, MO 63010.

Record date

Documented details

  • Outcome: Paid in full

Available findings

  • HVACCompleted work$514

    Trip fee, 2 pole 24V contactor supplied, and 2 pounds of additional R-410A refrigerant added to the system.

  • HVACWork status not resolved

    Photograph shows a Yellow Jacket manifold gauge set, vacuum pump, and digital gauge (reading 208) connected to an HVAC system at an outdoor condenser pad, indicating refrigerant service or system evacuation in progress.

  • HVACWork status not resolved

    Photograph shows a two-pole electrical contactor inside an outdoor HVAC condensing unit with heavy dust accumulation, visibly worn/pitted contact surfaces, and multiple wiring connections including white, red, orange, yellow, brown, and purple conductors.

  • HVACWork status not resolved

    Live R410A refrigerant diagnostic shows suction pressure 96.5 psi (vapor saturation 29.8°F), liquid pressure 270.0 psi (liquid saturation 88.7°F), suction line temp 57.3°F, liquid line temp 84.9°F, superheat 27.5°F, and subcooling 3.8°F recorded via Testo 557s.

  • HVACWork status not resolved

    Photograph shows a Testo digital manifold gauge connected to an HVAC refrigerant system, displaying low-side pressure of 97.5, high-side pressure of 284.3, temperatures of 30.2°F and 92.2°F, superheat of 24.7°F, and subcooling of 10.3, with blue, red, and yellow refrigerant hoses attached outdoors near gravel and concrete block.

View 2045 Oak Drive, Arnold, MO 63010 on Fresh House