Fresh House Property Summary
Highlights selected from 2 documented records for this property.
- HVAC · The furnace underwent seasonal heating maintenance in October 2026, including burner and flame sensor… · Oct 2026
- HVAC · The furnace heat exchanger was documented at the same October 2026 visit as having significant rust around… · Oct 2026
- HVAC · The outdoor AC condenser was inspected and cleaned in June 2026 as part of a seasonal AC maintenance visit. · Jun 2026
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 2 documented records for 2353 Banon Drive, St. Charles, MO 63301, dated in October 2026. The amount summary includes $435 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Maintenance Service — AC maintenance, outdoor condenser cleaned
- HVAC
Built from Housecall Pro data
- $145HVACAC maintenance performed: checked out and cleaned the outdoor condenser.
- HVACPhotograph shows Fieldpiece app screen displaying live R-410A refrigerant diagnostics: suction pressure 104.9 psig, liquid pressure 285.8 psig, actual superheat 13.5°F, actual subcooling 17.2°F; air-side note indicates supply air dry bulb (52.1°F) is above target (47.2°F), suggesting low capacity.
HVACOnly original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Heating Maintenance — Heat exchanger rust, possible failure
- HVAC
- $290HVACSeasonal heating maintenance performed: filter checked (clean), lines blown with CO2, humidifier pad #35 replaced and switched to winter mode, burners and flame sensor cleaned, gas pressure tested at 3.6 in. WC, temperature rise measured at 41°F; heat exchanger found with significant rust around rivets and weak points with possibility of failing soon; blower motor capacitor measured at 8.61 μF (>10% below 10 μF rating) and was replaced at customer's request.
Only original contributor can modify this entry
Create an account to manage your contributions over time
Only the original contributor can modify this entry · Create an account to manage your contributions over time.