HVAC Repair Invoice — Condenser fan motor + dual capacitor replaced
- HVAC
- Plumbing
On August 25, 2026, Arch Air Services documented HVAC and Plumbing at 2362 Rockdale Avenue, St. Louis, MO 63121.
- Record date
Available findings
- HVACCompleted work$1,421
Replaced dual capacitor and condenser fan motor (Prime Fit 1075), performed condenser coil cleaning (level 1), installed condensate pump without drain line, and completed diagnostic service call at 2362 Rockdale Ave.
- HVACWork status not resolved
Photograph shows the top of an outdoor HVAC condenser unit with a large fan blade assembly and protective grille, condenser fins visible around the perimeter, exposed wiring near the fan center, and a yellow electrical testing instrument (multimeter or clamp meter) resting on the unit.
- PlumbingWork status not resolved
Photograph shows a small white pump unit (possibly a condensate or utility pump) with copper piping above it and electrical wiring, situated on a concrete floor in what appears to be a basement or utility room.
- HVACWork status not resolved
Photograph shows two cylindrical capacitors (one large, one small) mounted with zip-tie straps inside an HVAC unit's electrical compartment, with multiple colored wires (pink/red, yellow, white, black) connected.
- HVACWork status not resolved
Photograph shows the exterior condenser coil fins of an air conditioning unit; fins on the right side of the coil are visibly bent, splayed, and deformed rather than uniform and straight.