- HVAC · Furnace inspection found a cracked heat exchanger needing replacement · Feb 2026
- HVAC · Water heater flue pipe found completely cracked, replacement needed · Feb 2026
- HVAC · AC system was found frozen over and refrigerant added · Sep 2025
RECORD SUMMARY
Fresh House preserves inspections, repairs, and appraisals so a home's history is never lost.
This page contains 2 documented records for 2413 Ackerman Avenue, St. Louis, MO 63114, dated in September 2025. The amount summary includes $593 in completed work across HVAC; appraisal values and permit-declared valuations are excluded.
HVAC Service Call — AC frozen over; R410a added
- HVAC
Built from Housecall Pro data
- $439HVACService call for no AC found the system completely frozen over; added R410a refrigerant by the pound (2 lbs) and the appointment was moved to re-evaluate.
Only original contributor can modify this entry
Create an account to manage your contributions over time
HVAC Service Call — Cracked heat exchanger; cracked water heater flue
- HVAC
Built from Housecall Pro data
- $154HVACService call for furnace making weird sounds at start up; inspection found a cracked heat exchanger and a completely cracked water heater flue pipe that needs replacement.
- HVACPhotograph shows heavily dust-coated sheet metal ductwork and galvanized round flue/exhaust pipes with visible cobwebs in what appears to be a basement mechanical area, with a furnace or air handler unit visible in the background.
- HVACPhotograph shows a visible crack or fracture in what appears to be a metal structural beam or bearing element at the junction of an overhead structure and wall, with red-painted structural components and galvanized pipes visible in the background.
- HVACPhotograph shows heavily corroded and rusted metal flue/exhaust pipe elbow with orange-brown deterioration at the joint, surrounded by galvanized sheet metal ductwork and round duct sections with cobwebs throughout; a work light is visible suggesting an active inspection.
- HVACPhotograph shows a heavily rusted and corroded metal flue or exhaust pipe with deteriorated insulation at the elbow joint, alongside galvanized HVAC ductwork in a basement mechanical space.
- HVACPhotograph shows galvanized sheet metal HVAC plenum and round branch duct with a visible torn/jagged gap at their junction, along with a corroded vertical pipe, cobwebs, and dust accumulation throughout the space.
- HVACPhotograph shows a handheld Carbon Monoxide Meter displaying a reading of approximately 103 ppm with the red alarm indicator illuminated, held near what appears to be an HVAC/furnace unit with visible vents in the background.